806f030c-08860001 Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].Explanation: Memory test failed in DIMM 1 of mem card 6.May also be shown as 806f030c08860001 or 0x806f030c08860001Severity: ErrorAlert Category: CriticalServiceable: NoCIM Information: Prefix: PLAT and ID: 0136SNMP Trap ID: 41Automatically notify Support: NoUser response:1. Refer to TIP H212293 for minimum code level.2. Check the IBM support site for any applicable retain tip or firmware update that applies to this memory error.3. Swap the affected DIMM with a similar DIMM (size/type) on a different channel.4. Re-enable all DIMM slots.5. If the failure remains on the original slot, replace the DIMM that was not moved. If the failure follows the DIMMthat was moved, replace the DIMM that was swapped.6. If the problem re-occurs with the same DIMM connector, inspect DIMM connector for foreign material. Ifdamaged, replace the board.806f030c-08860002 Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].Explanation: Memory test failed in DIMM 2 of mem card 6.May also be shown as 806f030c08860002 or 0x806f030c08860002Severity: ErrorAlert Category: CriticalServiceable: NoCIM Information: Prefix: PLAT and ID: 0136SNMP Trap ID: 41Automatically notify Support: NoUser response:1. Refer to TIP H212293 for minimum code level.2. Check the IBM support site for any applicable retain tip or firmware update that applies to this memory error.3. Swap the affected DIMM with a similar DIMM (size/type) on a different channel.4. Re-enable all DIMM slots.5. If the failure remains on the original slot, replace the DIMM that was not moved. If the failure follows the DIMMthat was moved, replace the DIMM that was swapped.6. If the problem re-occurs with the same DIMM connector, inspect DIMM connector for foreign material. Ifdamaged, replace the board.806f030c-08860001 • 806f030c-08860002548 IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Problem Determination and Service Guide