806f040c-1881001d [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName].Explanation: DIMM 29 in memory expansion module(MEU) has been Disabled.May also be shown as 806f040c1881001d or 0x806f040c1881001dSeverity: InfoAlert Category: SystemServiceable: NoCIM Information: Prefix: PLAT and ID: 0131SNMP Trap ID:Automatically notify Support: NoUser response:1. Make sure the DIMM is installed correctly.2. If the DIMM was disabled because of a memory fault, follow the suggested actions for that error event and restartthe server.3. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMMthrough the Setup utility or the Advanced Settings Utility (ASU).806f040c-1881001e [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName].Explanation: DIMM 30 in memory expansion module(MEU) has been Disabled.May also be shown as 806f040c1881001e or 0x806f040c1881001eSeverity: InfoAlert Category: SystemServiceable: NoCIM Information: Prefix: PLAT and ID: 0131SNMP Trap ID:Automatically notify Support: NoUser response:1. Make sure the DIMM is installed correctly.2. If the DIMM was disabled because of a memory fault, follow the suggested actions for that error event and restartthe server.3. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMMthrough the Setup utility or the Advanced Settings Utility (ASU).806f040c-1881001d • 806f040c-1881001e624 IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Problem Determination and Service Guide