806f030c-08880003 Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].Explanation: Memory test failed in DIMM 3 of mem card 8.May also be shown as 806f030c08880003 or 0x806f030c08880003Severity: ErrorAlert Category: CriticalServiceable: NoCIM Information: Prefix: PLAT and ID: 0136SNMP Trap ID: 41Automatically notify Support: NoUser response:1. Refer to TIP H212293 for minimum code level.2. Check the IBM support site for any applicable retain tip or firmware update that applies to this memory error.3. Swap the affected DIMM with a similar DIMM (size/type) on a different channel.4. Re-enable all DIMM slots.5. If the failure remains on the original slot, replace the DIMM that was not moved. If the failure follows the DIMMthat was moved, replace the DIMM that was swapped.6. If the problem re-occurs with the same DIMM connector, inspect DIMM connector for foreign material. Ifdamaged, replace the board.806f030c-08880004 Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].Explanation: Memory test failed in DIMM 4 of mem card 8.May also be shown as 806f030c08880004 or 0x806f030c08880004Severity: ErrorAlert Category: CriticalServiceable: NoCIM Information: Prefix: PLAT and ID: 0136SNMP Trap ID: 41Automatically notify Support: NoUser response:1. Refer to TIP H212293 for minimum code level.2. Check the IBM support site for any applicable retain tip or firmware update that applies to this memory error.3. Swap the affected DIMM with a similar DIMM (size/type) on a different channel.4. Re-enable all DIMM slots.5. If the failure remains on the original slot, replace the DIMM that was not moved. If the failure follows the DIMMthat was moved, replace the DIMM that was swapped.6. If the problem re-occurs with the same DIMM connector, inspect DIMM connector for foreign material. Ifdamaged, replace the board.806f030c-08880003 • 806f030c-08880004Appendix B. Integrated management module error messages 557