806f0a07-0301ffff [ProcessorElementName] is operating in a Degraded State.Explanation: The processor 1 is being throttled due to thermal or power conditions.May also be shown as 806f0a070301ffff or 0x806f0a070301ffffSeverity: WarningAlert Category: WarningServiceable: YesCIM Information: Prefix: PLAT and ID: 0038SNMP Trap ID: 42Automatically notify Support: NoUser response: Check the IMM event log for any fan, cooling, or power related issues.For a thermal condition:1. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place andcorrectly installed.2. Make sure that the room temperature is within operating specifications.For a power condition:1. If Power Supply Unit is rated 1400 Watt, Make sure it is connected to 220V AC input2. If using a 900 Watt rated power supply (connected at either 110V or 220 V ), may need to upgrade to a 1400 Wattrated power supply (connected at 220V).806f0a07-0302ffff [ProcessorElementName] is operating in a Degraded State.Explanation: The processor 2 is being throttled due to thermal or power conditions.May also be shown as 806f0a070302ffff or 0x806f0a070302ffffSeverity: WarningAlert Category: WarningServiceable: YesCIM Information: Prefix: PLAT and ID: 0038SNMP Trap ID: 42Automatically notify Support: NoUser response: Check the IMM event log for any fan, cooling, or power related issues.For a thermal condition:1. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place andcorrectly installed.2. Make sure that the room temperature is within operating specifications.For a power condition:1. If Power Supply Unit is rated 1400 Watt, Make sure it is connected to 220V AC input2. If using a 900 Watt rated power supply (connected at either 110V or 220 V ), may need to upgrade to a 1400 Wattrated power supply (connected at 220V).806f0a07-0301ffff • 806f0a07-0302ffff740 IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Problem Determination and Service Guide