Table 21. CA000000 to CA2799FF checkpoints (continued)v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed inthe Action column until the problem is solved. If an action solves the problem, you can stop performing theremaining actions.v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and whichcomponents are FRUs.Progress code Description ActionCA00E136 Create BSR node 1. Go to “Checkout procedure” on page 184.2. Replace the system-board, as described in“Replacing the FRU system-board andchassis assembly” on page 260.CA00E137 Create HEA node 1. Reboot the blade server.2. If the problem persists:a. Go to “Checkout procedure” on page184.b. Replace the system-board, as describedin “Replacing the FRU system-boardand chassis assembly” on page 260.CA00E138 Create options node 1. Go to “Checkout procedure” on page 184.2. Replace the system-board, as described in“Replacing the FRU system-board andchassis assembly” on page 260.CA00E139 Create aliases node and system aliases 1. Go to “Checkout procedure” on page 184.2. Replace the system-board, as described in“Replacing the FRU system-board andchassis assembly” on page 260.CA00E13A Create packages node 1. Go to “Checkout procedure” on page 184.2. Replace the system-board, as described in“Replacing the FRU system-board andchassis assembly” on page 260.CA00E13B Create HEA node 1. Reboot the blade server.2. If the problem persists:a. Go to “Checkout procedure” on page184.b. Replace the system-board, as describedin “Replacing the FRU system-boardand chassis assembly” on page 260.CA00E13C Create HEA port node 1. Reboot the blade server.2. If the problem persists:a. Go to “Checkout procedure” on page184.b. Replace the system-board, as describedin “Replacing the FRU system-boardand chassis assembly” on page 260.CA00E140 Loading operating system Go to “Boot problem resolution” on page 190.Chapter 2. Diagnostics 107