v Follow the suggested actions in the order in which they are listed in the Action column until the problem issolved.v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and whichcomponents are FRUs.v If an action step is preceded by “(Trained service technician only),” that step must be performed only by atrained service technician.IsolationProcedure Code Symptom ActionIf the SRC is B1xxB107 or B1xxB108The system has detected a problem with a clock card.1. Replace the system board and chassis assembly, as described in“Replacing the FRU system-board and chassis assembly” on page260.If the SRC is B1xxB106The system has detected that the planars are deconfigured.1. Replace the system board and chassis assembly, as described in“Replacing the FRU system-board and chassis assembly” on page260.If the SRC is B1xxB110 or B1xxB111The system has detected that all of the I/O bridges are deconfigured.1. Replace the system board and chassis assembly, as described in“Replacing the FRU system-board and chassis assembly” on page260.FSPSP02 This procedure is forboot failures thatterminate very earlyin the boot process orwhen themanagement card orthe VPD data on themanagement card isnot operational or isnot present.1. Replace the management card, as described in “Removing the tier 2management card” on page 255 and “Installing the tier 2management card” on page 256.2. After replacing the card and installing the blade server in the chassisunit and before rebooting the blade server or performing otheroperations, ensure that the initialization of the management cardVPD occurs by waiting for the management module to discover theblade server. Otherwise, the system might fail to IPL.3. If the problem persists, replace the system board and chassisassembly, as described in “Replacing the FRU system-board andchassis assembly” on page 260.FSPSP03 A system operator oruser error hasoccurred.Refer to the documentation for the function you were attempting toperform.FSPSP04 A problem has beendetected in theservice processorfirmware.1. Verify that the operating system is running. If it is running, performan in-band firmware update, as described in “Updating thefirmware” on page 263.2. If the problem persists, replace the system board and chassisassembly, as described in “Replacing the FRU system-board andchassis assembly” on page 260.FSPSP05 The service processorhas detected aproblem in theplatform firmware.1. Verify that the operating system is running. If it is running, performan in-band firmware update, as described in “Updating thefirmware” on page 263.2. If the problem persists, replace the system board and chassisassembly, as described in “Replacing the FRU system-board andchassis assembly” on page 260.Chapter 2. Diagnostics 203