v Follow the suggested actions in the order in which they are listed in the Action column until the problem issolved.v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and whichcomponents are FRUs.v If an action step is preceded by “(Trained service technician only),” that step must be performed only by atrained service technician.IsolationProcedure Code Symptom ActionFSPSP06 The service processorreported a suspectedintermittent problem.Contact IBM Support.FSPSP07 The time of day hasbeen reset to thedefault value.1. Use the chdate command to set the Virtual I/O Server date and time,using one of the following syntaxes:chdate [-year YYyy][-month mm][-day dd][-hour HH][-minute MM][-timezone TZ]chdate mmddHHMM[YYyy|yy][-timezone TZ]2. If the problem persists, replace the battery, as described in“Removing the battery” on page 250 and “Installing the battery” onpage 251.FSPSP09 A problem has beendetected with amemory DIMM, butit cannot be isolatedto a specific memoryDIMM.Replace the CRU called out after this FSPSP call. If the CRU that iscalled out is a DIMM CRU, perform the following procedure:1. Replace both memory DIMMs of the pair on the microprocessor thatcontains the failing CRU:DIMM 1 (Px-C1)For P1-C1, replace DIMMs 1 and 3; for P2-C1, replaceDIMMs 9 and 11.DIMM 2 (Px-C2)Replace DIMMs 2 and 4, or DIMMs 10 and 12.DIMM 3 (Px-C3)Replace DIMMs 1 and 3, or DIMMs 9 and 11.DIMM 4 (Px-C4)Replace DIMMs 2 and 4, or DIMMs 10 and 12.DIMM 5 (Px-C5)Replace DIMMs 5 and 7, or DIMMs 13 and 15.DIMM 6 (Px-C6)Replace DIMMs 6 and 8, or DIMMs 14 and 16.DIMM 7 (Px-C7)Replace DIMMs 5 and 7, or DIMMs 13 and 15.DIMM 8 (Px-C8)Replace DIMMs 6 and 8, or DIMMs 14 and 16.2. See “Removing a memory module” on page 244 for locationinformation and the removal procedure.3. Install new memory DIMMs, as described in “Installing a memorymodule” on page 245.See “Supported DIMMs” on page 4 for more information.204 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)