2. From the Function Selection menu, select Task Selection and press Enter.3. From the Tasks Selection List menu, select Update and Manage System Flash and press Enter.The Update and Manage System Flash menu is displayed. The top of the window displays thesystem firmware level for the PERM and the TEMP images and the image that the blade server usedto start.Note: If the TEMP image level is more current than the PERM image, commit the TEMP image.See “Committing the TEMP system firmware image.”4. When you have verified the firmware levels, press F3 until the Diagnostic Operating Instructionswindow is displayed; then press F3 again to exit the diagnostic program.Committing the TEMP system firmware imageAfter updating the system firmware and successfully starting up the blade server from the TEMP image,copy the TEMP image to the PERM image using the diagnostics program commit function.Note: If you install the server firmware update permanently by committing the temporary firmware levelfrom the temporary side to the permanent side, the temporary and permanent sides contain the samelevel of firmware. You cannot return to the level that was previously on the permanent side.1. Load the diagnostics program. See “Running the diagnostics program” on page 186.2. From the Function Selection menu, select Task Selection and press Enter.3. From the Tasks Selection List menu, select Update and Manage System Flash and press Enter.4. From the Update and Manage System Flash menu, select Commit the Temporary Image and pressEnter.5. When the commit function is complete, press F3 until the Diagnostic Operating Instructions screen isdisplayed; then press F3 again to exit the diagnostic program.Solving shared BladeCenter resource problemsProblems with BladeCenter shared resources might appear to be in the blade server, but might actually bea problem in a BladeCenter unit component.This information provides procedures to help you isolate blade server problems from shared BladeCenterresource problems.If the problem is thought to be with a shared resource, see the online information center or the ProblemDetermination and Service Guide or the Hardware Maintenance Manual and Troubleshooting Guide for yourBladeCenter unit, or see the documentation for BladeCenter unit components for additional information.If the problem cannot be solved, see “Solving undetermined problems” on page 227.To check the general function of shared BladeCenter resources, complete the following operations.1. Verify that the BladeCenter unit has the required power modules installed and is connected to aworking power source.222 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)