Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem issolved. If an action solves the problem, then you can stop performing the remaining actions.v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and whichcomponents are FRUs.Error code Description ActionBA090001 SCSD DASD: test unit ready failed;hardware error 1. Go to “Checkout procedure” on page 184.2. Replace the system-board, as described in“Replacing the FRU system-board andchassis assembly” on page 260.BA090002 SCSD DASD: test unit ready failed;sense data available 1. Go to “Checkout procedure” on page 184.2. Replace the system-board, as described in“Replacing the FRU system-board andchassis assembly” on page 260.BA090003 SCSD DASD: send diagnostic failed;sense data available 1. Go to “Checkout procedure” on page 184.2. Replace the system-board, as described in“Replacing the FRU system-board andchassis assembly” on page 260.BA090004 SCSD DASD: send diagnostic failed:devofl cmd 1. Go to “Checkout procedure” on page 184.2. Replace the system-board, as described in“Replacing the FRU system-board andchassis assembly” on page 260.BA09000A There was a vendor specification error. 1. Check the vendor specification foradditional information.2. If the problem persists:a. Go to “Checkout procedure” on page184.b. Replace the system-board, as describedin “Replacing the FRU system-boardand chassis assembly” on page 260.BA09000B Generic SCSD sense error 1. Verify that the SCSD cables and devices areproperly plugged.2. Correct any problems that are found.3. If the problem persists:a. Go to “Checkout procedure” on page184.b. Replace the system-board, as describedin “Replacing the FRU system-boardand chassis assembly” on page 260.BA09000C The media is write-protected 1. Change the setting of the media to allowwriting, then retry the operation.2. Insert new media of the correct type.3. If the problem persists:a. Go to “Checkout procedure” on page184.b. Replace the system-board, as describedin “Replacing the FRU system-boardand chassis assembly” on page 260.64 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)