Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem issolved. If an action solves the problem, then you can stop performing the remaining actions.v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and whichcomponents are FRUs.Error code Description ActionBA040060 Setting the firmware boot side for thenext boot failed. 1. Go to “Checkout procedure” on page 184.2. Replace the system-board, as described in“Replacing the FRU system-board andchassis assembly” on page 260.BA050001 Failed to reboot a partition in logicalpartition mode 1. Go to “Checkout procedure” on page 184.2. Replace the system-board, as described in“Replacing the FRU system-board andchassis assembly” on page 260.BA050004 Failed to locate service processor devicetree node. 1. Go to “Checkout procedure” on page 184.2. Replace the system-board, as described in“Replacing the FRU system-board andchassis assembly” on page 260.BA05000A Failed to send boot failed message 1. Go to “Checkout procedure” on page 184.2. Replace the system-board, as described in“Replacing the FRU system-board andchassis assembly” on page 260.BA060008 No configurable adapters found by theRemote IPL menu in the SMS utilitiesThis error occurs when the firmware cannotlocate any LAN adapters that are supported bythe remote IPL function. Verify that the devicesin the remote IPL device list are correct usingthe SMS menus.BA06000B The system was not able to find anoperating system on the devices in theboot list.Go to “Boot problem resolution” on page 190.BA06000C A pointer to the operating system wasfound in non-volatile storage. 1. Go to “Checkout procedure” on page 184.2. Replace the system-board, as described in“Replacing the FRU system-board andchassis assembly” on page 260.BA060020 The environment variable “boot-device”exceeded the allowed character limit. 1. Go to “Checkout procedure” on page 184.2. Replace the system-board, as described in“Replacing the FRU system-board andchassis assembly” on page 260.BA060021 The environment variable “boot-device”contained more than five entries. 1. Go to “Checkout procedure” on page 184.2. Replace the system-board, as described in“Replacing the FRU system-board andchassis assembly” on page 260.Chapter 2. Diagnostics 61