Table 25. 101-711 through FFC-725 SRNs (continued)SRN FFC Description and Action651-734 292 Intermediate or system bus data parity error. Go to “Performing the checkoutprocedure” on page 184.651-735 292 Intermediate or system bus time-out error. Go to “Performing the checkoutprocedure” on page 184.651-736 292 Intermediate or system bus time-out error. Go to “Performing the checkoutprocedure” on page 184.651-740 2D3 Note: Ensure that the system IPLROS and service processor are at the latestfirmware level before removing any parts from the system.651-741 2D3 Service processor error accessing special registers. Go to “Performing the checkoutprocedure” on page 184.651-742 2D3 Service processor reports unknown communication error. Go to “Performing thecheckout procedure” on page 184.651-743 2D5 Service processor error accessing Vital Product Data EEPROM. Go to “Performingthe checkout procedure” on page 184.651-745 2D9 Service processor error accessing power controller. Go to “Performing the checkoutprocedure” on page 184.651-746 2D4 Service processor error accessing fan sensor. Go to “Performing the checkoutprocedure” on page 184.651-747 2D5 Service processor error accessing thermal sensor. Go to “Performing the checkoutprocedure” on page 184.651-748 2E2 Service processor error accessing voltage sensor. Go to “Performing the checkoutprocedure” on page 184.651-750 2D4 Service processor detected NVRAM error. Go to “Performing the checkoutprocedure” on page 184.651-751 2D4 Service processor error accessing real-time clock/time-of-day clock. Go to“Performing the checkout procedure” on page 184.651-752 2D4 Service processor error accessing JTAG/COP controller/hardware. Go to“Performing the checkout procedure” on page 184.651-753 151 2D4 Service processor detects loss of voltage from the time-of-day clock backup battery.Go to “Performing the checkout procedure” on page 184.651-770 292 Intermediate or system bus address parity error. Go to “Performing the checkoutprocedure” on page 184.651-771 292 Intermediate or system bus data parity error. Go to “Performing the checkoutprocedure” on page 184.651-772 292 Intermediate or system bus time-out error. Go to “Performing the checkoutprocedure” on page 184.651-773 227 Intermediate or system bus data parity error. Go to “Performing the checkoutprocedure” on page 184.651-780 2C7 214 Uncorrectable memory error. Go to “Performing the checkout procedure” on page184.651-781 2C7 214 Uncorrectable memory error. Go to “Performing the checkout procedure” on page184.651-784 302 214 Uncorrectable memory error. Go to “Performing the checkout procedure” on page184.651-785 303 214 Uncorrectable memory error. Go to “Performing the checkout procedure” on page184.134 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)