Table 14. B200xxxx Logical partition SRCs (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem issolved. If an action solves the problem, then you can stop performing the remaining actions.v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and whichcomponents are FRUs.B200 xxxxReference Code Description ActionB2001142 A problem occurred during themigration of a partition.The migration of a partition did notcomplete.Check for server firmware updates; then, install theupdates if available.B2001143 A problem occurred during themigration of a partition.The migration of a partition did notcomplete.Check for server firmware updates; then, install theupdates if available.B2001144 A problem occurred during themigration of a partition.The migration of a partition did notcomplete.Check for server firmware updates; then, install theupdates if available.B2001148 A problem occurred during themigration of a partition.The migration of a partition did notcomplete.Check for server firmware updates; then, install theupdates if available.B2001150 During the startup of a partition, apartitioning configuration problemoccurred.Go to “Verifying the partition configuration” on page 186.B2001151 A problem occurred during themigration of a partition.The migration of a partition did notcomplete.Check for server firmware updates; then, install theupdates if available.B2001170 During the startup of a partition, afailure occurred due to a validationerror.Go to “Verifying the partition configuration” on page 186.B2001225 A problem occurred during thestartup of a partition.The partition attempted to start upprior to the platform fullyinitializing. Restart the partition afterthe platform has fully completed andthe platform is not in standby mode.Restart the partition.B2001230 During the startup of a partition, apartitioning configuration problemoccurred; the partition is lacking thenecessary resources to start up.Go to “Verifying the partition configuration” on page 186.B2001260 A problem occurred during thestartup of a partition.The partition could not start at theTimed Power On setting because thepartition was not set to Normal.Set the partition to Normal.30 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)