Table 27. A00-FF0 through A24-xxx SRNs (continued)SRN Description FRU/actionA11-550 Recoverable errors on resource indicatea trend toward an unrecoverable error.However, the resource could not bedeconfigured and is still in use. Thesystem is operating with the potentialfor an unrecoverable error.1. If repair is not immediately available, rebootand the resource will be deconfigured;operations can continue in a degraded mode.2. Check the BladeCenter management-moduleevent log for an entry around this time. If noentry is found, replace the system-board andchassis assembly.A12-00x A non-critical error has been detected.Error log analysis indicates an errordetected by the memory controller, butthe failure could not be isolated.1. Check the BladeCenter management-moduleevent log; if an error was recorded by thesystem, see “POST progress codes(checkpoints)” on page 84.2. If no entry is found, Replace thesystem-board.A12-01x A non-critical error has been detected,an uncorrectable memory error. 1. Check the BladeCenter management-moduleevent log; if an error was recorded by thesystem, see “POST progress codes(checkpoints)” on page 84.2. If no entry is found, Replace thesystem-board.A12-02x A non-critical error has been detected,an ECC correctable error. 1. Check the BladeCenter management-moduleevent log; if an error was recorded by thesystem, see “POST progress codes(checkpoints)” on page 84.2. If no entry is found, Replace thesystem-board.A12-03x A non-critical error has been detected, acorrectable error threshold exceeded. 1. Check the BladeCenter management-moduleevent log; if an error was recorded by thesystem, see “POST progress codes(checkpoints)” on page 84.2. If no entry is found, Replace thesystem-board.A12-04x A non-critical error has been detected, amemory control subsystem internalerror.1. Check the BladeCenter management-moduleevent log; if an error was recorded by thesystem, see “POST progress codes(checkpoints)” on page 84.2. If no entry is found, Replace thesystem-board.A12-05x A non-critical error has been detected, amemory address error (invalid addressor access attempt).1. Check the BladeCenter management-moduleevent log; if an error was recorded by thesystem, see “POST progress codes(checkpoints)” on page 84.2. If no entry is found, Replace thesystem-board.A12-06x A non-critical error has been detected, amemory data error (bad data going tomemory).1. Check the BladeCenter management-moduleevent log; if an error was recorded by thesystem, see “POST progress codes(checkpoints)” on page 84.2. If no entry is found, Replace thesystem-board.Chapter 2. Diagnostics 167