6.3 Periodic MaintenanceThe drive has various "maintenance monitors." This feature provides advance maintenancewarning and eliminates the need to shut down the entire system for unexpected problems. Thedrive allows the user to check the following maintenance periods.• Cooling Fan• Electrolytic Capacitors (Main Circuit)• Inrush Prevention Circuit• IGBTu Replacement PartsTable 6.3 contains the estimated performance life of components that require replacementduring the life of the drive. Only use Yaskawa replacement parts for the appropriate drivemodel and revision.Table 6.3 Estimated Performance LifeComponent Estimated Performance LifeCooling Fan 2 ~ 3 yearsElectrolytic Capacitors (Main Circuit) 10 years <1><1> The drive has few serviceable parts and may require complete drive replacement.NOTICE: Estimated performance life based on specific usage conditions. These conditions are provided forthe purpose of replacing parts to maintain performance. Some parts may require more frequent replacementdue to poor environments or rigorous use.Usage conditions for estimated performance life:• Ambient temperature: Yearly average of 30 °C• Load factor: 80% maximum• Operation time: 12 hours a dayn Performance Life MonitorsThe drive calculates the maintenance period for components that may require replacementduring the life of the drive. A percentage of the maintenance period is displayed on the LEDdigital operator by viewing the appropriate monitor parameter.When the maintenance period reaches 100%, there is increased risk that the drive maymalfunction. Yaskawa recommends checking the maintenance period regularly to ensuremaximum performance life.Refer to Recommended Periodic Inspection on page 156 for more details.Table 6.4 Performance Life Monitors Used for Component ReplacementParameter Component ContentsU4-04 Cooling Fan Displays the accumulated cooling fan operation time as a percentage of thespecified maintenance period (displayed in percent %).U4-05 Main Circuit (DC bus)Electrolytic Capacitors Displays the accumulated time the capacitors are used as a percentage of thespecified maintenance period.6.3 Periodic MaintenanceYASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 1596 Periodic Inspection &Maintenance