u d: ReferencesReference parameters are used to set the various frequency reference values during operation.No. Name Description Range Def. Mode Addr.Hex Pg.V/fd1: Frequency ReferenceUse d1 parameters to configure the drive frequency reference.d1-01<22> FrequencyReference 1 Frequency reference0.00 to400.00Hz<19>0.00Hz S 280 96d1-02<22> FrequencyReference 2Frequency reference when digital input "Multi-StepSpeed Reference 1" (H1-oo = 3) is on.0.00Hz S 281 96d1-03<22> FrequencyReference 3Frequency reference when digital input "Multi-StepSpeed Reference 2” (H1-oo = 4) is on.0.00Hz S 282 96d1-04<22> FrequencyReference 4Frequency reference when digital inputs "Multi-StepSpeed Reference 1, 2" (H1-oo = 3 and 4) are on.0.00Hz S 283 96d1-05<22> FrequencyReference 5Frequency reference when digital input "Multi-StepSpeed Reference 3" (H1-oo = 5) is on.0.00Hz O 284 —d1-06<22> FrequencyReference 6Frequency reference when digital inputs "Multi-StepSpeed Reference 1, 3 " (H1-oo = 3 and 5) are on.0.00Hz O 285 —d1-07<22> FrequencyReference 7Frequency reference when digital inputs "Multi-StepSpeed Reference 2, 3" (H1-oo = 4 and 5) are on.0.00Hz O 286 —d1-08<22> FrequencyReference 8Frequency reference when multi-function input"Multi-Step speed reference 1, 2, 3" (H1-oo = 3, 4,5) are on.0.00Hz O 287 —d1-17<22> Jog FrequencyReferenceFrequency reference when digital inputs "JogFrequency Reference", "Forward Jog" or "ReverseJog." are on.6.00Hz S 292 —d2: Frequency Upper and Lower LimitsUse d2 parameters to configure the frequency reference limits.d2-01 FrequencyReferenceUpper LimitSets the frequency reference upper limit as apercentage of maximum output frequency (E1-04).Output speed is limited to this value even if thefrequency reference is higher. This limit applies to allfrequency reference sources.0.0 to110.0 100.0% O 289 —d2-02 FrequencyReferenceLower LimitSets the frequency reference lower limit as apercentage of maximum output frequency (E1-04).Output speed is limited to this value even if thefrequency reference is lower. This limit applies to allfrequency reference sources.0.0 to110.0 0.0% O 28A —d3: Jump FrequencyUse d3 parameters to configure the drive Jump Frequency settings.d3-01 JumpFrequency 1 d3-01 to d3-04 allow programming of three prohibitedfrequency reference points for eliminating problemswith resonant vibration of the motor/machine. Thisfeature does not eliminate the selected frequencyvalues, but accelerates and decelerates the motorthrough the prohibited bandwidth.The parameters must be according to the ruled3-01 ≥ d3-02 .0.0 to400.00.0Hz O 294 —d3-02 JumpFrequency 2 0.0Hz O 295 —B.2 Parameter TableYASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 203B Parameter List