2.2 Mechanical InstallationThis section outlines specifications, procedures, and environment for proper mechanicalinstallation of the drive.u Installation EnvironmentTo help prolong the optimum performance life of the drive, install the drive in the properenvironment. The table below provides a description of the appropriate environment for thedrive.Table 2.1 Installation EnvironmentEnvironment ConditionsInstallation Area IndoorsAmbientTemperature-10 °C to +50 °C (IP20/Open-Chassis)Drive reliability improves in environments without wide temperature fluctuations.When using an enclosure panel, install a cooling fan or air conditioner in the area to ensure thatthe air temperature inside the enclosure does not exceed the specified levels.Do not allow ice to develop on the drive.Humidity 95% RH or less and free of condensationStorage Temperature -20 °C to +60 °CSurrounding AreaInstall the drive in an area free from:• oil mist and dust• metal shavings, oil, water or other foreign materials• radioactive materials• combustible materials (e.g., wood)• harmful gases and liquids• excessive vibration• chlorides• direct sunlightAltitude 1000 m or lowerVibration 10 to 20 Hz at 9.8 m/s220 to 55 Hz at 5.9 m/s2Orientation Install the drive vertically to maintain maximum cooling effects.NOTICE: Prevent foreign matter such as metal shavings or wire clippings from falling into the drive duringinstallation and project construction. Failure to comply could result in damage to the drive. Place a temporarycover over the top of the drive during installation. Remove the temporary cover before startup, as the coverwill reduce ventilation and cause the drive to overheat.2.2 Mechanical InstallationYASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 332 Mechanical Installation