7.5.2 Steps of the OPC UA configurationWhen using the Siemens SIMATIC Manager, the OPC UA configuration happens by thefollowing steps:1. Create your project in the Siemens SIMATIC Manager with the corresponding hard-ware configuration.Ä Chap. 4.5 ‘Hardware configuration - CPU’ page 692. Configure the corresponding Ethernet connection for PG/OP communication andestablish an online connection.Ä Chap. 4.7 ‘Hardware configuration - EthernetPG/OP channel’ page 723. Save translate and transfer your project.Ä Chap. 4.10 ‘Project transfer’ page 904. Call the external OPC UA Configurator from the Siemens SIMATIC Manager. Forthis click in the hardware configurator on the CPU from VIPA and select‘Start Device Tool è VIPA Framework è OPC UA Configurator’.5. Confirm to start an external program with [YES].NOTICE!Data exchange between platforms of different vendorsIf you allow access, you permit the exchange of data betweenOPC UA Configurator and your project data of the SiemensSIMATIC Manager.– Ensure that the necessary security guidelines are compliedwith.ð The OPC UA Configurator is started. For the OPC UA configuration, the data istaken from the Siemens SIMATIC Manager project and listed in the table for theOPC UA configuration.Please note that only the objects of the LD, FBD and IL lan-guages can be transferred to the OPC UA Configurator.6. Configure the OPC UA server and the data for the OPC UA communication.7. In the OPC UA Configurator switch to the online dialog and transfer the OPC UAconfiguration. For communication the IP address data are taken from the SiemensSIMATIC Manager project.ð The OPC UA configuration is now complete. For check you will find informationabout your OPC UA configuration on the device web page at ‘OPC UA’ .Ä Chap. 4.11.1.1.1 ‘Tab: ‘OPC UA’ ’ page 977.6 Usage in Siemens TIA PortalSiemens TIA Portal from version V15.0 and VIPA SPEED7 Studio from V1.8.6n The OPC UA configuration happens by the external OPC UA Configurator from VIPA.n The OPC UA Configurator is the SPEED7 Studio reduced to OPC UA functionality.n The OPC UA Configurator can be registered in the Siemens TIA Portal by means ofthe SPEED7 Tools Integration.n The OPC UA Configurator is to be called from the Siemens TIA Portal after projectcreation and online configuration.n The OPC UA Configurator automatically imports the data for the OPC UA configura-tion from the project data of the Siemens TIA Portal.n The OPC UA configuration is transferred online from the OPC UA Configurator. Forthe communication the OPC UA Configurator automatically uses the IP address dataof the Siemens TIA Portal project.Steps of configurationPreconditionVIPA System SLIO Deployment OPC UAUsage in Siemens TIA PortalHB300 | CPU | 013-CCF0R00 | en | 19-30 195