- Notes on the instruction manual
- Safety
- Intended use
- Target group / Qualifications of personnel
- Safety instructions
- Information on protection of the environment
- Setup and function
- Device versions
- Device overview
- Control elements
- Functions
- Support rings
- Technical data
- Dimensional drawings
- Connection, installation / mounting
- Installation site
- Mounting / dismantling
- Electrical connection
- Mounting
- Mounting/installation in flush-mounted installation box
- Dismantling
- Surface-mounted installation
- Labelling inlay
- Commissioning
- Assigning the group address(es)
- Updating options
- Operation
- Colour concept
- Operating modes
- Display overview
- Switching On and Off
- Adjust temperature
- Adjusting the fan speed levels
- Eco mode
- Changing the operating status (heating/cooling)
- Maintenance
- Description of application and parameters
- Use of automatic enable/blockage
- Use object for switchover time
- Overwrite switchover time at download
- Brightness of the LED during blockage
- LED colour in a blocked state
- Day/Night mode
- Alarm function
- LED brightness during alarm
- LED colour during alarm
- Cycle time
- Actual temperature value above
- Adjusting the temperature unit via object
- Communication object data type
- Display relative humidity
- Display time
- Display backlighting day
- Display backlighting red
- Primary function - Application
- Object type
- Reaction on rising edge
- Reaction on falling edge
- Value 1/Value 2
- Value 2
- General — Device function
- General - Control function
- General - Operating mode after reset
- General - Additional functions/objects
- General — Delay time for read telegrams after reset
- General — Object "Effective operating mode" active
- RTC — Heating control
- Heating control - Heating type
- Heating control - I-component (min.)
- Basic stage heating
- Basic stage heating - Hysteresis (x 0.1°C)
- Basic stage heating - PWM cycle heating (min)
- Control of additional heating stage
- Control of additional heating stage — Additional heating type
- Control of additional heating stage — I-component (min)
- Additional heating stage
- Additional heating stage — Cyclic sending of the control value (min)
- Cooling control
- Cooling control — Cooling type
- Cooling control — I-component (min.)
- Basic stage cooling
- Basic stage cooling — Hysteresis (x 0.1°C)
- Basic stage cooling - PWM cycle cooling (min)
- Basic stage cooling — Maximum control value (0 - 255)
- Control of additional cooling stage
- Control of additional cooling stage — Cooling type
- Control of additional cooling stage — P-component (min)
- Additional cooling stage
- Additional cooling stage — Cyclic sending of the control value (min)
- Settings of basic load
- Combined heating and cooling modes
- Combined heating and cooling modes — Heating/cooling control value output
- Setpoint settings
- Setpoint settings — Hysteresis for switchover heating/cooling (x 0.1°C)
- Setpoint settings — Reduction for standby heating (°C)
- Setpoint settings — Set-point temperature for frost protection (°C)
- Setpoint settings — Increase for standby cooling (°C)
- Setpoint settings - Setpoint adjustment via communication object (DPT 9.001)
- Setpoint settings - Basic set value is
- Setpoint adjustment
- Setpoint adjustment — Maximum manual reduction during cooling mode (0 - 9°C)
- Setpoint adjustment - Setpoint adjustment via communication object
- Setpoint adjustment — Resetting the manual adjustment via object
- Temperature reading — Inputs of weighted temperature reading
- Temperature reading — Weighting of external measurement 2 (0 to 100%)
- Temperature reading — Adjustment value for internal temperature measurement (x 0.1°C)
- Temperature reading — Operating mode for fault
- Alarm functions
- Alarm functions — Frost alarm temperature for HVAC and RHCC status (°C)
- Temperature limiter
- Temperature limiter - Temperature limit of heating - Integral component of the PI controller
- Temperature limiter - Temperature limit of additional heating stage
- Temperature limiter - Temperature limit of cooling - Limit temperature
- Temperature limiter - Temperature limit of additional cooling stage
- Fan coil settings - Number of fan devices
- Fan coil settings - Fan speed levels
- Fan coil settings - Fan speed levels — Level output
- Fan coil settings heating
- Fan coil settings for heating - Maximum speed level heating for eco mode
- Fan coil settings for cooling
- Fan coil settings for cooling - Maximum fan speed level cooling for eco mode
- Summer compensation
- Summer compensation - (Lower) Starting temperature for summer compensation (x 0.1°C)
- Summer compensation - (Upper) Exit temperature for summer compensation (x 0.1°C)
- CO2 sensor — CO2 sensor
- CO2 sensor — CO2 error
- CO2 sensor — Send the CO2 value cyclic
- CO2 sensor — Weighting of external measured value
- CO2 controller — CO2 controller type
- CO2 controller — Send control value at switchover
- CO2 controller — Send control value at change
- CO2 controller — Send control value cyclic
- Settings— Switch command below threshold 1
- Settings — Value below threshold 1 (-255) for output format byte
- CO2 — CO2 threshold 1
- Settings — Value for output format switching command
- Settings — Value for output format byte
- CO2 — CO2 threshold 2
- CO2 — CO2 threshold 3
- Settings — Value for output format priority
- Settings — Value for output format scene
- Behaviour at setting the blockage
- PI controller — Readjust time (15...240 min)
- PI controller - Minimum control value
- PI controller - Maximum control value
- PI controller — Control value at measurement failure
- Relative humidity - Relative humidity sensor
- Relative humidity - Send relative humidity at change
- Relative humidity - Send relative humidity cyclic
- Relative humidity - Component
- Relative humidity — Control value output format
- Relative humidity controller — Send control value at change
- Relative humidity controller — Send control value at change of byte
- Relative humidity controller — Send control value cyclic
- Relative humidity controller - Hysteresis (symetrical)
- Step controller — Switch command below threshold 1
- Step controller — Value below threshold 1 (byte)
- Step controller — RH threshold 1
- Step controller — Switch command above threshold 1
- Step controller — Value above threshold 1 (scene)
- Step controller — RH threshold 2
- Step controller — Switch command above threshold 2
- Step controller — Percent above threshold 2
- Step controller — RH threshold 3
- Step controller — Switch command above threshold 3
- Step controller — Priority at measurement failure
- Step controller - Percentage at measurement value failure
- Step controller — Value above threshold 3 (byte)
- Step controller - Value at measurement value failure (scene)
- Behaviour at removing the blockage
- Dew point temperature — Dew point sensor
- Dew point — Cyclically send dew point temperature
- Dew point alarm — Dew point alarm
- Dew point alarm — Send dew point alarm cyclic
- Dew point alarm — Switch command at the end of the dew point alarm
- Dew point alarm — Scene for dew point alarm (1 - 64)
- Application "Function block x
- Function block x - Application
- Application - 2-button switching
- Application - 1-button switching
- Application - 2-button dimming
- Manner of dimming
- Step size for step-wise dimming (%)
- Dimming function
- Working mode of the buttons for switching
- Dimming stop telegram
- Duration of telegram repetition
- Application - 1-button dimming
- Application - 2-button blind
- Duration of long operation
- Working mode of the buttons
- Value for slats position down (%)
- Application - 1-button blind
- Value for position down (%)
- Application - 2-button value transmitter
- Application - 1-button value transmitter
- Application - 1-button value transmitter, 2 objects
- Object type for rising/falling edge
- Value 1/value 2 for rising edge
- Value 1/value 2 for falling edge
- Application - 2-button value dimming sensor
- Step size (%)
- Application - 1-button light scene extension unit with memory function
- Light scene memory function
- Application - 2-button step switch
- Evaluation period
- Object values
- Application - 1-button step switch
- Bit pattern of the object values
- Application - 1-button multiple operation
- Object type for object x
- Function for object type 1-bit for object x
- Value for object x
- Application - 1-button short-long operation
- Reaction on short operation
- Reaction on long operation
- Value 1/value 2 for short operation
- Value 1/value 2 for long operation
- Application - 1-button operating mode "Adjust RTC
- Object type for output
- Operating mode
- Enable object
- Enable object after return of voltage
- Send Eco object
- Application - 2-button RTC function internal
- Application - 1-button RTC function internal
- Application - LED function
- Object type for status object
- Brightness of the colours
- Colour for On
- Colour for Zone 1 (corresponds to 0%)
- Colour for Zone 2 (starting at 1%)
- Colour for Zone 3
- Colour for Zone 4 (up to 99%)
- Colour for Zone 5 (corresponds to 100%)
- Colour of function illumination
- Send measured values
- Cycle time for sending of the actual temperature
- Overwriting internal object
- Channel x - Application
- Application - Cyclic telegrams
- Value for cyclic sending
- Application - Priority
- Application - Logic gate
- Logical function
- Initial value input x
- Object type output
- Value of the output object for logic true
- Value of the output object for logic untrue
- Application - Gate
- Filter function
- Data flow direction
- Object value enable object
- Save input signal
- Application - Staircase lighting
- Object type/number
- Retriggering
- Time for switch-off pre-warning (s)
- Application - Delay
- Delay time
- Overwrite delay time during download
- Application - Min/max value transducer
- Output sends
- Application - Light scene actuator
- Number of actuator groups
- Object type actuator group x
- Scene can be saved
- Value
- DS - Temperature value
- DS - Display day/night
- LED - Alarm
- EF - Enable
- HB - In operation
- PF - Switching
- RTC — Status control value of basic heating stage
- RTC — Status control value of additional cooling stage
- RTC - External actual temperature
- RTC - Current setpoint
- RTC - Superimposed operating mode
- RTC - Window contact
- RTC - Presence detector
- RTC - Basic load
- RTC - Fan manual (heating)
- RTC - Fan speed level status (heating)
- RTC - Dew point alarm
- RTC - Summer compensation active
- RTC - Setpoint display
- RTC - Confirm setpoint
- RTC - Request manual fan speed level
- RTC - Controller status RHCC
- RTC -Setpoint for heating comfort
- RTC -Setpoint for cooling comfort
- RTC — Setpoint error
- RTC - Limit temperature additional cooling stage
- RTC - Fan speed level x (cooling)
- CO2 — CO2 value
- CO2 - threshold 1
- RH - Relative humidity value
- RH - Threshold 1
- button dimming - Switching
- button blind — Adjustment/slats position/stop
- button value transmitter - Switching
- button value transmitter, 2 objects - Switching (falling edge)
- button multiple operation - Switching 1 actuation
- button light scene extension unit with memory function - Light scene number
- button operating mode "Adjust RTC" — Operating mode Eco
- button switching - Switching
- button blind — Adjustment/slats position
- button step switch - Switching step x
- LED function - Status LED
- Temperature sensor - Actual temperature
- Cyclic telegrams — Enable
- Logic gate - Output
- Gate - Input
- Gate - Output
- Staircase lighting - Switch-off delay
- Delay - Input
- Delay - Delay time
- Min/max value transducer - Input x
- Notes
- Index
Related products
ClimaECO SB/Ux.0.1 SeriesClimaECO SBS/Ux.0.1 SeriesClimaECO SBR/Ux.0.1 Series4690 SeriesAP200 SeriesKEVA 36 G2 SeriesABB-free@home WBI-S-1-xx-WL SeriesABB-free@home BI-S-1-xx-WL SeriesTOTALFLOW LevelMaster Seriesfree@home 180 flex 62762-WL-500 SeriesABB categories
Industrial Equipment
DC Drives
Controller
Relays
Measuring Instruments
Circuit breakers
Battery Charger
Industrial Electrical
Transformer
Switch
manualsdatabase
Your AI-powered manual search engine