Chapter 7 Servo ParametersRevision June 2010 7-67Bit12Bit12: Input power phase loss detection function0: Enable Input power phase loss (AL022) detection function1: Disable Input power phase loss (AL022) detection functionBit13Bit13: Encoder output error detection function0: Enable encoder output error (AL018) detection function1: Disable encoder output error (AL018) detection functionBit15 Bit14Bit14 ~ Bit15: Reserved. Must be set to 0.P2 - 66 GBIT2 Special Function 2 Address: 0284H, 0285HDefault: 0 Related Section: N/AApplicable Control Mode: PT, SUnit: N/ARange: 0 ~ 0x000FData Size: 16-bitDisplay Format: HexadecimalSettings:Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0Bit1 Bit0Bit0 ~ Bit1: Reserved. Must be set to 0.Bit2Bit2: Undervoltage (Servo Drive Fault) clear mode selection0: The fault, Undervoltage will not be cleared automatically.1: The fault, Undervoltage will be cleared automatically.Bit7 Bit6 Bit5 Bit4 Bit3Bit3 ~ Bit7: Reserved. Must be set to 0.