Chapter 7 Servo ParametersRevision June 2010 7-69Group 3: P3-xx Communication ParametersP3 - 00 ADR Communication Address Setting Address: 0300H, 0301HDefault: 0x7F Related Section: Section 8.2Applicable Control Mode: ALLUnit: N/ARange: 0x01 ~ 0x7FData Size: 16-bitDisplay Format: HexadecimalSettings:This parameter is used to set the communication slave address in hexadecimalformat. This address is an absolute address which represents the servo drive on aRS-232/485 or CANbus network.Display 0 0 Y XRange - - 0 ~ 7 0 ~ FX: Axis number, the value must be within the range from 0 through F.Y: Group number, the value must be within the range from 0 to through 7If the AC servo drive is controlled by RS-232/485 communication, each drive (ordevice) must be uniquely identified. One servo drive only can set one address. Ifthe address is duplicated, there will be a communication fault.Please note:1. This parameter does not provide broadcast function and does not respondinsecurity.2. When the address of host (external) controller is set to 0xFF, it is withauto-respond function. Then, the servo drive will receive from and respond tohost (external) controller both no matter the address is matching or not.However, the parameter P3-00 cannot be set to 0xFF.P3 - 01 BRT Transmission Speed Address: 0302H, 0303HDefault: 0x0203 Related Section: Section 8.2Applicable Control Mode: ALLUnit: bpsRange: 0x0000 ~ 0x0055Data Size: 16-bitDisplay Format: HexadecimalSettings:This parameter is used to set the baud rate and data transmission speed of thecommunications.