8-26 TroubleshootingError Message during Disk Array ConfigurationWhen an error is detected during the automatic Disk Array Configuration of the Easy Setup process,any of the following messages appears. An illegal device status exists in the status table. An illegal status is returned during the Configuration Data read. Configured device(s) is not responded. The configuration in NvRAM does not agree with the configuration in EEPROM. The number of pack configuring disks is 0 or 9 or above. An error occurs during the configuration table read. The configuration table in NvRAM cannot be read. An illegal RAID level exists in the configuration table. An error occurs during the CONFIG2 table transfer. The adapter is not responded. A CONFIG2 checksum error occurred. Adapter is not exists.When one of above messages is observed, the Disk Array controller or the hard disk drive may befailed. Check that cable connections and switch settings are correct, and then attempt to run NECEXPRESSBUILDER once again.Problems with Master Control MenuThe master control menu fails to appear:T Is your system Windows NT 4.0 or later, or Windows 95 or later?→ The menu is only able to run on Windows NT 4.0 (or later) or Windows 95 (orlater).T Is Shift pressed?→ Setting the CD-ROM with Shift pressed down cancels the Autorun feature.T Is the system in the proper state?→ The menu may not appear depending on the system registry setting or the timingto set the CD-ROM. In such a case, start the Explorer and run \MC\1ST.EXE inthe CD-ROM.