B3 SYSTEM ADMINISTRATION—SETTING COS (CLASS OF SERVICE) PARAMETERS274 Installation ManualMessage Length 1-6 min0: Unlimited(6)Defines the maximum message length.If set to "0: Unlimited", a manager can record two-wayconversations of unlimited length into his or another person’smailbox (Two-Way Recording or Two-Way Transfer). Themaximum recording time for other messages will automaticallybe set to 6 min.Mailbox CapacityMaximumMessages5-100 msgs(100)Specifies the maximum number of (both new and saved)messages that can be stored in a mailbox.Mailbox CapacityMaximumMessage Time5-100 min0: Unlimited(100)Specifies the total number of available minutes for storing(both new and saved) messages in each mailbox.MessageRetrieval Order1. LIFO2. FIFO(LIFO)Specifies the order in which messages will be retrieved (playedback for listening).LIFO: Messages are retrieved starting with the mostrecent.FIFO: Messages are retrieved starting with the oldest.MessageScanning withInformation1. Yes2. No(No)If set to "Yes", the VPS adds the message sender’s name andthe recording date and time to the message during themessage scan.Prompt Mode 1. System2. User 13. User 2(User 1)Specifies the language used for voice prompts.NoteIf User 1 or User 2 is specified as Prompt Mode but notrecorded by the Message Manager, the VPS willautomatically play the factory-recorded System promptsin English.Delete MessageConfirmation1. Yes2. No(No)If set to "Yes", the VPS requests confirmation from the mailboxowner before erasing a message left in the mailbox. If set to"No", the message is erased immediately.Table B-7Parameter Value Range(Default)Description/Function