April 20172-95Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer 012-302B , 012-303Status Indicator RAPsLaunch Issue012-302B Front Cover Interlock Open RAPBSD-ON: BSD 13.3 Office Finisher LX Interlock SwitchingInitial ActionsNOTE: Ensure the correct RAP is performed, refer to the 012-302 Front Cover Interlock OpenEntry RAP.WARNINGEnsure that the electricity to the machine is switched off while performing tasks that donot need electricity. Refer to GP 10. Disconnect the power cord. Electricity can causedeath or injury. Moving parts can cause injury.• Check the installation of the front door interlock switch, PL 13.45 Item 19.• Check that the front cover can be opened and closed.ProcedureEnter dC330 code 012-302. Open then close the finisher front cover to actuate the front doorinterlock switch. The display changes.Y NCheat the front door interlock switch. The display changes.Y NCheck the wiring between J8982 pin 3 and J8891 pin 2B, and from J8891 pin 2A toJ8982 pin 2 for an open or short circuit, or a loose or damaged connector. The wir-ing is good.Y NReconnect or repair as necessary.Remove the cheater. Measure the voltage between J8891 pin 2A on the front doorinterlock switch and ground. The voltage is approximately +5VDC.Y NCheck the wiring from J8891 pin 2A to J8982 pin 3 for an open or short circuit,or a loose or damaged connector. If the wires are good, install a new finisherPWB, PL 13.45 Item 2.Cheat the interlock switch. The voltage drops to 0VDC.Y NInstall a new front door interlock switch, PL 13.45 Item 19.Install a new finisher PWB, PL 13.45 Item 2.Check the actuator for damage or misalignmentCheck the interlock circuit for an intermittent condition. If the fault persists, install a new finisherPWB, PL 13.45 Item 2.012-303 Finisher horizontal Transport Cover Open RAPBSD-ON: BSD 13.5 Office Finisher LX Horizontal Transport012-303 The finisher horizontal transport cover is open.Initial ActionsWARNINGEnsure that the electricity to the machine is switched off while performing tasks that donot need electricity. Refer to GP 10. Disconnect the power cord. Electricity can causedeath or injury. Moving parts can cause injury.• Check the installation of the horizontal transport open sensor, PL 13.08 Item 3.• Check that the finisher horizontal transport cover can be opened and closedProcedureEnter dC330 code 012-303. Actuate the horizontal transport open sensor. The displaychanges.Y NCheck the wiring between J8860 pin 2 and J8897 pin 2 for an open or short circuit, or aloose or damaged connector. The wiring is good.Y NReconnect or repair as necessary.Measure the voltage between J8897 pins 3 and 1 on the finisher PWB. The voltage isapproximately +5VDC.Y NInstall a new finisher PWB, PL 13.45 Item 2.Measure the voltage between J8897 pin 2 on the finisher PWB and ground. Actuate thehorizontal transport open sensor. The voltage changes.Y NInstall a new horizontal transport open sensor, PL 13.08 Item 3.Install a new finisher PWB, PL 13.45 Item 2.If the fault persists, install a new finisher PWB, PL 13.45 Item 2.