April 20172-507Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer 116-325, 116-330, 331, 336, 337, 339Status Indicator RAPsLaunch Issue116-325 ESS Fan Fail RAPBSD-ON: BSD 3.9 ESS116-325 An error occurred in the rotation of the ESS fan.ProcedureWARNINGEnsure that the electricity to the machine is switched off while performing tasks that donot need electricity. Refer to GP 10. Disconnect the power cord. Electricity can causedeath or injury. Moving parts can cause injury.Perform the steps that follow:1. Switch off, then switch on the machine, GP 10.2. Check the wiring between P/J311 on the ESS PWB and the ESS fan for an open or shortcircuit, or a loose or damaged connector.3. If the fault persists, install new components as necessary:• ESS fan, PL 3.10 Item 9.• ESS PWB, PL 3.10 Item 6.116-330, 331, 336, 337, 339 HDD File System Fail RAP116-330 HDD check at power on detected that an error has occurred or the HDD was not for-matted.116-331 A log related error was detected.116-336 An error was detected when the HDD was accessed.116-337 Overall SNTP fatal error. Due to an error in software processing, subsequent pro-cesses cannot be performed.116-339 When the JBA is started up, the HDD is not installed.ProcedurePerform the 016-210, 506, 777, 780, 798 HDD Error RAP.