8 Parameter8.10 Application Parameters8-53155223-1CDRE-CSO-A036 AxP011, AxP012: MANUAL WIRE OPERATION SPEEDThese parameters specify the manual wire operation speed as a percentage of the maximuminstruction value. Instruction polarity is determined by the current instruction in the Power Sourcecharacteristic file. The setting range is from 0 to 100. AxP013, AxP014: WELDING CONTROL TIMEThese parameters specify the welding control time in units of minutes. The setting range is from 0 to999. AxP015 to AxP017: NUMBER OF WELDING CONTROLThese parameters specify the number of welding controls. The setting range is from 0 to 99. AxP026 to AxP029: TOOL ON/OFF USER OUTPUT NO. (Jiglesssystem)These parameters specify the user output number for the tool open/close operation by specific keys.8.10.2 Handling Application AxP002, AxP004: f1 KEY FUNCTIONThese parameters set the output signal to assign for f1 key.0: Not specified1 to 4: Specific outputs for HAND-1 to HAND4-15: User output (No. is specified by AxP004). AxP003, AxP005: f2 KEY FUNCTIONThese parameters set the output signal to assign for f2 key.0: Not specified1 to 4: Specific outputs for HAND-2 to HAND4-25: User output (No. is specified by AxP005)8.10.3 Spot Welding AxP003: MAXIMUM NUMBERS OF CONNECTED POWERSOURCESThe initial value is set to 4. The value is automatically set at start-up. No modification is needed. AxP004: GUN FULL OPEN STROKE ON/OFF SIGNALThis parameter specifies which stroke switching signal is output ON or OFF to make the gun fully-opened for each gun.Bit specification (1 for 01) for 8 guns. The initial setting is “0.”0 0 0 0 0 0 0 0| | | | | | | |8 7 6 5 4 3 2 1 Gun number341 of 435