9 Painting Application9.9 Painting System Setting File9-42155223-1CDRE-CSO-A0369.9 Painting System Setting File(1) GUN TYPESets the gun type.“SPRAY” or “BELL” can be selected.(2) PAINT SUPPLYSets the paint supplying device.“UNUSED” or “FGP” can be selected, however, normally select “UNUSED.”• When “UNUSED” is selectedThe paint supplying device is controlled by the paint control panel. Therefore, control ofthe amount of discharge from the NX100 is controlled by the I/O output.• When “FGP” is selectedThe paint supplying device, FGP, is controlled by the NX100. The amount of discharge iscontrolled by the servo.(3) CCV NUMBER (Setting range: 0 to 52)Sets the number of CCVs (the number of painting colors) to be connected. When a CCV isconnected to the paint control panel, set the CCV number to zero.(4) BELL ROTATION OUTPUTSets the output method to control the number of bell rotations.“I/O OUTPUT” or “LEVEL” can be selected.• When “I/O OUTPUT” is selectedThe paint control panel controls the number of bell rotations. The set number of bellrotations (krpm) is output for the output bit specified in the painting system characteristicssetting file.• When “LEVEL” is selectedThe paint control panel controls the number of bell rotations. The level value that was setis output for the output bit specified in the painting system characteristics setting file.Short CutMain MenuDATA EDIT DISPLAY UTILITYVARIABLEB001IN/OUTIn OutROBOTCFFD/CFSETUPDISPLAY SETUPA aPAINTING PARAMETERSYSTEM INFORJOBDOUTMOVEENDPAINT SYSTEM CONFG.GUN1PAGEGUN TYPE BELLPAINT SUPPLY UNUSEDCCV NUMBER 0BELL ROTATION OUTPUT I/O OUTPUTSHAPING OUTPUT I/O OUTPUT(1)(2)(3)(4)(5)384 of 435