514 | Remote Monitoring (RMON)w w w . d e l l . c o m | s u p p o r t . d e l l . c o mshow rmon hc-alarmDisplay the contents of RMON High-Capacity Alarm Table.Syntax show rmon hc-alarm [index] [brief]ParametersDefaults noneCommand Modes EXECCommand HistoryExample 1 Figure 27-6. show rmon hc-alarm brief Command ExampleExample 2 Figure 27-7. show rmon hc-alarm index Command Exampleshow rmon historyDisplay the contents of the RMON Ethernet History table.Syntax show rmon history [index] [brief]ParametersDefaults noneindex (OPTIONAL) Enter the table index number to display just that entry.brief (OPTIONAL) Enter the keyword brief to display the RMON High-CapacityAlarm Table in an easy-to-read format.Version 8.3.16.1 Introduced on MXL 10/40GbE Switch IO ModuleFTOS#show rmon hc-alarm briefindex SNMP OID--------------------------------------------------------------------1 1.3.6.1.2.1.1.32 1.3.6.1.2.1.1.33 1.3.6.1.2.1.1.34 1.3.6.1.2.1.1.35 1.3.6.1.2.1.1.3FTOS#FTOS#show rmon hc-alarm 1RMON high-capacity alarm entry 1object: 1.3.6.1.2.1.1.3sample interval: 5sample type: absolute value.value: 185638alarm type: rising or falling alarm.alarm rising threshold value: positive.rising threshold: 1001, RMON event index: 1alarm falling threshold value: positive.falling threshold: 999, RMON event index: 6alarm sampling failed 0 times.alarm owner: 1alarm storage type: non-volatile.alarm status: OKFTOS#index (OPTIONAL) Enter the table index number to display just that entry.brief (OPTIONAL) Enter the keyword brief to display the RMON EthernetHistory table in an easy-to-read format.