CHAPTER 5: SETTINGS469 MOTOR MANAGEMENT RELAY – INSTRUCTION MANUAL 5–43Custom Overload CurveIf the SELECT CURVE STYLE is set to “Custom” in the Thermal Model, the following settingswill appear:PATH: SETTINGS ZV S5 THERMAL MODEL ZV OVERLOAD CURVE SETUPOVERLOAD [TIME TO TRIP AT1.01 x FLA:Range: 0.5 to 99999.9 s in steps of 0.1MESSAGE TIME TO TRIP AT1.05 x FLA:Range: 0.5 to 99999.9 s in steps of 0.1MESSAGE TIME TO TRIP AT1.10 x FLA:Range: 0.5 to 99999.9 s in steps of 0.1MESSAGE TIME TO TRIP AT1.20 x FLA: 795.4Range: 0.5 to 99999.9 s in steps of 0.1MESSAGE TIME TO TRIP AT1.30 x FLA: 507.2Range: 0.5 to 99999.9 s in steps of 0.1MESSAGE TIME TO TRIP AT1.40 x FLA: 364.6Range: 0.5 to 99999.9 s in steps of 0.1MESSAGE TIME TO TRIP AT1.50 x FLA: 280.0Range: 0.5 to 99999.9 s in steps of 0.1MESSAGE TIME TO TRIP AT1.75 x FLA: 169.7Range: 0.5 to 99999.9 s in steps of 0.1MESSAGE TIME TO TRIP AT2.00 x FLA: 116.6Range: 0.5 to 99999.9 s in steps of 0.1MESSAGE TIME TO TRIP AT2.25 x FLA: 86.1Range: 0.5 to 99999.9 s in steps of 0.1MESSAGE TIME TO TRIP AT2.50 x FLA: 66.6Range: 0.5 to 99999.9 s in steps of 0.1MESSAGE TIME TO TRIP AT2.75 x FLA: 53.3Range: 0.5 to 99999.9 s in steps of 0.1MESSAGE TIME TO TRIP AT3.00 x FLA: 43.7Range: 0.5 to 99999.9 s in steps of 0.1MESSAGE TIME TO TRIP AT3.25 x FLA: 36.6Range: 0.5 to 99999.9 s in steps of 0.1MESSAGE TIME TO TRIP AT3.50 x FLA: 31.1Range: 0.5 to 99999.9 s in steps of 0.1MESSAGE TIME TO TRIP AT3.75 x FLA: 26.8Range: 0.5 to 99999.9 s in steps of 0.1MESSAGE TIME TO TRIP AT4.00 x FLA: 23.3Range: 0.5 to 99999.9 s in steps of 0.1MESSAGE TIME TO TRIP AT4.25 x FLA: 20.5Range: 0.5 to 99999.9 s in steps of 0.1MESSAGE TIME TO TRIP AT4.50 x FLA: 18.2Range: 0.5 to 99999.9 s in steps of 0.1