MAP 1322: End of Call MAP for Systems with Service Focal PointNote: If you are working on a system that not managed by an HMC go to ″MAP 0410: Repair Checkout″in the RS/6000 Eserver pSeries Diagnostic Information for Multiple Bus SystemsStep 1322-1For future reference, record the SRC or symptom and the location code of the FRU you replaced.Step 1322-2For Service Focal Point operating instructions, refer to “Service Focal Point” on page 43. At the HMC,open Service Focal Point and examine the service action event log for any open service action events.Step 1322-3Are there any service action events that are open?No If the system attention LED is still on, use the HMC to turn off the LED as described in “Resettingthe System Attention LED” on page 50. This completes the repair, return the system to thecustomer.Yes Go to “Step 1322-4”.Step 1322-4Record the list of open service action events.Step 1322-5From the list of serviceable events recorded in “Step 1322-4,” perform “Step 1322-6” through “Step1322-33” on page 96 for each open service action event.Step 1322-6Determine the error class of the serviceable event. Record for future use.Step 1322-7Examine the details of the open service action event.Is the error code associated with this service action event the same as recorded in ″Step 1322-1″?No Go to “Step 1322-8.”Yes Go to “Step 1322-11” on page 94.Step 1322-8Examine the FRU list of the service action event.Are there any FRUs listed for the service action event?No Go to “Step 1321-11” on page 81.Yes Go to “Step 1321-9” on page 81.Chapter 3. Maintenance Analysis Procedures (MAPs) 93