EYFR03 User Manual 27 of 110 v1.6.0Chapter 3: Configuring the unit 20 January 2020Forgetting ToolsEach tool can only be associated with a single qualifier at a time but learning a tool to anotherqualifier does not automatically remove it from the previous qualifier. If you have moved or areplanning to move a tool from one EYFR03 to another, you should have the qualifier “forget” thetool. To do so, press Forget on the Tool Configuration screen to remove the tool from thequalifier. This will cause the qualifier to no longer respond to the tool and will make anyparameters using the tool and any groups or jobs using those parameters invalid. If you learnAccuPulse in one-way mode “90” and want to relearn it in two-way mode “91”, you must“forget” the tool first. You cannot just “relearn”.ParametersSelecting ParametersFigure 22: Main Menu - Parameters Figure 23: Choose Parameter screenSoft keys1. Select – Select the currently highlighted parameter to run and return to the Run screen. Onlyavailable for selectable parameters.2. Edit – Edit the currently highlighted parameter.3. Copy – Selects the currently highlighted parameter to be copied to another location.4. Exit [ESC] – Returns to the Main Menu screen.The Choose Parameter screen shows all the parameters in the unit in a 10x10 grid. Parametersmay be highlighted by using the arrow keys to move the highlight to the desired parameter ortyping the number of the desired parameter. Only the parameters with tools assigned will showtheir numbers on the grid. A selectable parameter will have a black number. A defined but notselectable parameter will be shown in red. A parameter is defined when a tool number isassigned to it. If the assigned tool number is an empty tool slot, because either no tool was everlearned or the previous tool was forgotten, the parameter will become unselectable.Because parameters 1-16 are locked to tools 1-16 respectively, they will be blank if theassociated tool slot is empty.