EYFR03 User Manual 90 of 110 v1.6.0Chapter 7: EtherNet/IPTM 20 January 2020Max Angle CHAR[5] ASCII digits representing the value. Not used by the EYFR03.Units CHAR Character representing the units of the torque. Not used by the EYFR03 .Reserved USINTTotal size: 40 bytes151This connection point corresponds to the mask 1 of the EIP network card for the EYFR01.Name Data Type DescriptionParameter USINT Selects a parameter for the EYFR03 to run. May be any value in the ranges0-7, ‘0’-‘7’, ‘A’-‘H’ (see above for details). Values outside these rangeswill cause the current parameter to be stopped and leave no parameterrunning.Batch Reset USINT When this value changes, the batch will be reset.Suspend BOOL When true, suspends the EYFR03.Batch USINT The number of tightenings to run per batch for the selected parameter.Ignored if 0.Total size: 4 bytesInput Connection Points for Backwards CompatibilityThe connection points in this group correspond to the default masks provided in theEtherNet/IPTM network card for the EYFR01 and are provided to make the EYFR03 easier todrop into existing installations. These connection points are not recommended for newinstallations.100This connection point corresponds to the default mask of the EIP network card for the EYFR01.Name Data Type DescriptionParameter CHAR ‘A’-‘H’Tool Type CHAR[3] Type of the tool for the current parameter. One of:“AIR” – Pneumatic air tools“BAT” – Battery operated tool“CLK” – Click wrench“DIG” – Digital torque wrench“ “ – No parameter runningParameter Name CHAR[8] Name of the parameterTightening Status CHAR Status of the last tightening. One of:‘O’ – Good tightening‘N’ – Bad tightening or no tightening performed since the last parameterchangeTightening Type CHAR Type of the last tightening. One of:‘B’ – Good tightening that finished a batch‘C’ – Good tightening that did not finish a batch‘R’ – Bad tightening‘N’ – No tightening performed since the last parameter changeCount USINT The count of the last tightening.Batch USINT The batch size of the last tighteningRolling Count UINT Number of tightenings that have occurred.Total UINT Number of batches completed in the parameter.Time CHAR[6] ASCII digits of time of last tightening in HHMMSS format.Date CHAR[6] ASCII digits of date of last tightening in MMDDYY format.