EYFR03 User Manual 85 of 110 v1.6.0Chapter 7: EtherNet/IPTM 20 January 2020• 13x: Last tightening data with fixed length string fieldsInput Connection Points for Last Tightening DataThe connection points in this group will contain data about the last tightening. As such, they arenot updated after a parameter, group, or job selection until a tightening occurs.110 Name Data Type DescriptionTightening ID UDINT ID number of the last tighteningTime DT Timestamp of the last tighteningMulti SequenceNumberUINT Sequence number of the running multi-parameter operation.Multi Number UINT Instance number of multi-parameter operation (job or group) currentlyrunning. Ignored if 0.Multi Type USINT Type of multi-parameter operation currently running:1 – Group2 – JobIgnored if Multi-Number is 0.Parameter UINT Instance number of the parameter that produced the tighteningParameter Name SHORT_STRING Name of the parameter. Max length 25ParameterTimestampDT Timestamp of the last change to the parameterTool SerialNumberSHORT_STRING Serial number of the tool that produced the tightening. Max length 14Tightening Status BOOL Indicates if the last tightening was accepted as valid.Count USINT Number of results performed in the current batch for the parameter.Batch USINT Number of results required for a batch in the parameter.Torque Unit ENGUNIT Unit used for torque fieldsTorque REAL Torque of the tightening just performed.Min Torque REAL Minimum torque required for a tightening in the parameter.Max Torque REAL Maximum torque required for a tightening in the parameter.Angle UDINT Angle of the tightening just performed.Min Angle UDINT Minimum angle required for a tightening in the parameter.Max Angle UDINT Maximum angle required for a tightening in the parameter.VIN SHORT_STRING Max length 100Total size: 55-194 bytes111 Name Data Type DescriptionTightening ID UDINT ID number of the last tighteningTime DT Timestamp of the last tighteningMulti SequenceNumberUINT Sequence number of the running multi-parameter operation.Multi Number UINT Instance number of multi-parameter operation (job or group) currentlyrunning. Ignored if 0.Multi Type USINT Type of multi-parameter operation currently running:1 – Group2 – JobIgnored if Multi-Number is 0.Parameter UINT Number of the parameter that produced the tighteningTightening Status BOOL Indicates if the last tightening was accepted as valid.Count USINT Number of results performed in the current batch for the parameter.