EYFR03 User Manual 70 of 110 v1.6.0Chapter 6: Atlas Copco Open Protocol 20 January 2020Enable OP ControlDefault: YesThis setting determines if the unit will respond to “Open Protocol control” commands. Thesecommands are generally the ones that control unit operation or modify configuration. When thissetting is set to Yes, all supported commands listed below are handled. When set to No, thefollowing MID commands will return an error:• 0018 Parameter Select• 0019 Parameter Batch Size• 0020 Parameter Reset Batch• 0038 Job Select• 0039 Job Restart• 0042 Tool Disable• 0043 Tool Enable• 0050 VIN Download• 0082 Write Time• 0127 Job Abort• 0130 Job Off• 0150 Multi ID Download• 0156 Reset Latest Identifier• 0157 Reset All IdentifiersProtocol ModeDefault: 1This setting determines the mode used by the qualifier for Open Protocol connections. Thissetting should be left on the default unless specifically advised otherwise by the factory.