EYFR03 User Manual 44 of 110 v1.6.0Chapter 3: Configuring the unit 20 January 2020Reset DefaultsFigure 43: Reset Defaults screenSoft keys1. Reset All – Resets all configuration to factory defaults.2. No function3. Reset – Resets the selected parts of the configuration to factory defaults.4. Cancel [ESC] – Returns to the Qualifier Settings screen without resetting any configuration.The Reset Defaults screen allows you to restore the unit to the factory defaults. You may selectsome or all parts of the configuration to reset.Resetting some parts of the configuration may invalidate other parts that are not being reset.Resetting… May invalidate…Tools Parameters, Groups, JobsParameters Groups, JobsGroups JobsJobs noneQualifier Settings Tools1Network Settings noneTightenings noneEvents noneI/O Config noneVIN Selections none1 If the XBEE channel was changed from the default, the unit will go to the Channel Change screen to update thetools back to the default XBEE channel when resetting the default qualifier settings.