About indicator status90 - ENGLISHMaintenance■■ When there is a problem with internal powerThe status of the indicator is displayed with the following symbols.s: Off, ●: On, H: Flashing, ■: On or FlashingIndicatorStatus of the projectorGreenRedTEMP.>RedFILTER>OrangeBlueREPLACE>/REPLACE>OrangeH*1 ● H*1 H*1 H*1 H*1A problem has been detected within the projector.The projector will not turn back on even when pressingthe power button on the remote controlor the power button on the control panel.Remove the power plug from the outlet, and plug itback in again.If the power turns off, or the indicator turns on orflashes again, remove the power plug from the outletand contact your dealer to request an inspection andrepair. Do not leave the projector plugged in with theindicator on or flashing. Doing so may cause a fire orelectric shock.*1: The indicator will flash in approximately 0.5-second intervals.■■ When there is a problem with the air filterThe status of the indicator is displayed with the following symbols.s: Off, ●: On, H: Flashing, ■: On or FlashingIndicatorStatus of the projectorGreenRedTEMP.>RedFILTER>OrangeBlueREPLACE>/REPLACE>Orange■*1 ■*1 ■*1 ● ■*1 ■*1The indicator notifies you when the time set with [Filtercounter timer] ( page 83) has been reached. Replacethe air filter. ( will be shown at the top right of thescreen simultaneously.)Alternatively, the indicator notifies you when [Filtercounter remaining] becomes 0%. Replace the airfilter. ( will be shown at the top right of the screensimultaneously.*2 )*1: The indicator will turn on or flash under certain conditions, regardless of the status of other indicators.*2: When [Display] ( page 69) is set to [On], the freeze function ( page 47) or shutter function ( page 47) will not be displayed onthe screen during operation. PreviousNext |