August 20072-219WorkCentre 5687 Family 08-155A, 08-156A, 08-155B, 08-156BStatus Indicator RAPsFigure 3 Circuit diagram08-155B, 08-156B Bypass Tray Registration Jam RAP (65-87 ppm)08-155 The lead edge of the paper failed to actuate the registration sensor within the correcttime after start of feed from the bypass tray.08-156 The IOT detects that a sheet fed from the bypass has arrived to early at the registrationsensor.Initial Actions• Make sure that the correct RAP is used. To identify the correct RAP to use, go to the 08-155, 08-156 Bypass Tray Registration Jam Entry RAP.• Check the condition of the paper in the bypass tray. Refer to IQ1 and GP 20.• Check for obstructions in the paper path.• Check that the left hand door is latched correctly.• Check that the interlock cover has not come loose, PL 7.30 Item 23. Bias the cover to theright and tighten the two screws• Check that the short paper path assembly latches without excessive force, PL 10.25 Item1. Go to REP 10.1. In Replacement Step 5, check the latch mechanism.• If 08-155 is displayed, check the bypass tray empty actuator, 07C Bypass Tray RAP.ProcedureNOTE: The front door interlock must be cheated when checking +24V components.Enter dC330 code 08-150 registration sensor, Q08-150. Press Start. Figure 2. Activate the reg-istration sensor. The display changes.Y NGo to Flag 1. Check Q08-150. Refer to:• GP 11 How to Check a Sensor.• P/J16, IOT PWB.• 01E +5V Distribution RAP.• 01B 0V Distribution RAP.Install new components as necessary:• Registration sensor, (65-87 ppm) PL 8.17 Item 3.• Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL1.10 Item 2.Enter dC330 code 04-010 main drive motor, code 08-070 registration clutch, CL08-070. PressStart. The jam clearance knob, 4c, PL 8.17 Item 10, rotates.Y NGo to Flag 3. Check CL08-070. Refer to:• GP 12 How to Check a Solenoid or Clutch.• P/J5, IOT PWB.• P/J17 LVPS.• Fuse, PL 1.10 Item 9, GP 7.Enter dC330 code 08-050 feed solenoid, SOL08-050. Press Start. The solenoid energizes.