August 20072-494 WorkCentre 5687 Family11-180-170, 11-182-170Status Indicator RAPs11-180-170, 11-182-170 HCSS BM Eject Jam RAP11-180-170 A booklet is late to the HCSS BM eject sensor.11-182-170 A booklet is late from the HCSS BM eject sensor.Initial ActionsTurn the crease blade knob (6d) to ensure that the crease blade mechanism is free to move. Ifnecessary, clear any paper jam in the exit area.ProcedureEnter dC330 code 11-418. Actuate the BM crease blade motor encoder sensor, Q11-418, Fig-ure 1 by rotating the crease blade knob (6d). The display changes.Y NGo to Flag 1, check the sensor, Q11-418.Refer to:• GP 11, How to Check a Sensor.• P/J552, BM PWB.• 11C-170 HCSS BM Power Distribution RAP.Install new components as necessary:• BM PWB, PL 11.86 Item 10.• BM crease blade motor encoder sensor, PL 11.84 Item 1.Release the crease roll nip pressure by moving the crease roll handle fully counter clockwise.Remove the BM right hand cover, PL 11.88 Item 15, to access the crease rolls. Enter dC330code 11-419. Actuate the BM crease roll motor encoder sensor by rotating the crease rollsslowly by hand. The display changes.Y NGo to Flag 2, check the sensor, Q11-419.Refer to:• GP 11, How to Check a Sensor.• P/J552, BM PWB.• 11C-170 HCSS BM Power Distribution RAP.Install new components as necessary:• BM PWB, PL 11.86 Item 10.• BM crease roll motor encoder sensor, PL 11.86 Item 9.Enter dC330 code 11-386. Actuate the BM eject sensor, Q11-386, Figure 2. The displaychanges.Y NGo to Flag 3, check sensor, Q11-386.Refer to:• GP 11, How to Check a Sensor.• P/J556, BM PWB.• 11C-170 HCSS BM Power Distribution RAP.Install new components as necessary:• BM PWB, PL 11.86 Item 10.• BM eject sensor, PL 11.88 Item 17.Enter dC330, code 11-062 to run the BM crease roll motor, MOT 11-062. The motor runs.Y NGo to Flag 4, check the motor, MOT 11-062.Refer to:• GP 10 How to Check a Motor.• P/J557, BM PWB.• 11C-170 HCSS BM Power Distribution RAP.Install new components as necessary:• BM crease roll motor, PL 11.86 Item 12.• BM PWB, PL 11.86 Item 10.Enter dC330, code 11-061 to run the BM crease blade motor, MOT 11-061. The motor runs.Y NGo to Flag 5, check the motor, MOT 11-061.Refer to:• GP 10 How to Check a Motor.• P/J557, BM PWB.• 11C-170 HCSS BM Power Distribution RAP.Install new components as necessary:• BM crease blade motor, PL 11.84 Item 3.• BM PWB, PL 11.86 Item 10.Enter dC330, code 11-401 to run the BM crease roll gate motor, MOT 11-401. The motorruns.Y NGo to Flag 6 and Flag 7, check the motor, MOT 11-401.Refer to:• GP 10 How to Check a Motor.• P/J555, BM PWB.• 11C-170 HCSS BM Power Distribution RAP.Install new components as necessary:• BM crease roll gate motor, PL 11.86 Item 8.• BM PWB, PL 11.86 Item 10.The fault may be intermittent, check for damaged wiring or bad connectors, REP 1.2. If neces-sary install a new BM PWB, PL 11.86 Item 10.AA