August 20072-667WorkCentre 5687 Family 12-301Status Indicator RAPs12-301 Offset Catch Tray Failure RAP12-301 The offset catch tray has not made an index position within 450 ms of the last indexposition being made.Initial Actions• Check that the offset catch tray is correctly installed and there is no obstruction to preventmovement between offset positions. If the tray is damaged, install a new OCT PL 12.10Item 1.• 32-55 ppm Only. Make sure that the OCT fingers are installed correctly. Refer to REP12.1.ProcedureFigure 1. Go to Flag 1 and Flag 2. Check the OCT wiring, GP 7. The wiring is good.Y NRepair the wiring or install a new OCT, PL 12.10 Item 1.Enter dC330, code 12-005 to check the OCT motor, MOT12-005. MOT12-005 runs.Y NInstall a new OCT, PL 12.10 Item 1.Enter dC330, code 12-005 and stack code 12-301 to check the OCT index sensor, Q12-301.The display changes as the motor runs.Y NInstall a new OCT, PL 12.10 Item 1.Enter dC330, code 12-300 to check the OCT tray 90% full sensor, Q12-300. Actuate the sen-sor, Figure 1. The display changes.Y NCheck the sensor actuator. If necessary install a new OCT, PL 12.10 Item 1.Perform SCP 6 Final Actions RAP.Figure 1 Component locationOCT tray 90% full sensorQ12-300OCT motorMOT12-005OCT index sensorQ12-301