August 20072-422 WorkCentre 5687 Family11-334-130, 11-335-130, 11-336-130Status Indicator RAPs11-334-130, 11-335-130, 11-336-130 Bin 1 Elevate FailureRAP11-334-130 The bin 1 upper limit switch has been made.11-335-130 The bin 1 lower limit switch has been made.11-336-130 Bin 1 fails to move to the home position.Initial ActionsCheck that there is no damage or obstructions that prevent bin 1 from moving. If necessaryinstall a new bin 1 tray assembly, PL 11.52 Item 10.ProcedureEnter dC330, codes 11-030, 11-031, 11-032 and 11-033 to run the bin 1 elevator motor, MOT11-030. Check the movement of bin 1. Bin 1 moves correctly.Y NGo to Flag 3. Check the bin 1 elevator motor, MOT 11-030.Refer to:• GP 10, How to Check a Motor.• P/J424, HCSS PWB.• 11C-130 HCSS Power Distribution RAP.Install new components as necessary:• Bin 1 elevator motor, PL 11.52 Item 11.• HCSS PWB, PL 11.56 Item 5.Enter dC330, code 11-334, actuate the bin 1 upper limit switch, S11-334, Figure 1. The dis-play changes.Y NGo to Flag 2. Check the switch S11-334.Refer to:• GP 13, How to Check a Switch.• P/J424, HCSS PWB.• 11C-130 HCSS Power Distribution RAP.Install new components as necessary:• Bin 1 upper limit switch, PL 11.52 Item 1.• HCSS PWB, PL 11.56 Item 5.Enter dC330, code 11-335, actuate the bin 1 lower limit switch, S11-335, Figure 1. The dis-play changes.Y NGo to Flag 1. Check the switch S11-335.Refer to:• GP 13, How to Check a Switch.• P/J424, HCSS PWB.• 11C-130 HCSS Power Distribution RAP.Install new components as necessary:• Bin 1 lower limit switch, PL 11.52 Item 2.• HCSS PWB, PL 11.56 Item 5.Perform SCP 6 Final Actions.Figure 1 Component locationBin 1 lower limitswitch, S11-335Bin 1 upper limitswitch, S11-334Bin 1 elevatormotor, MOT11-030AA