August 20072-705WorkCentre 5687 Family 19-409, 19-710, 19-711Status Indicator RAPs19-409 Video Job Integrity Fault RAP19-409 Video determines that it cannot guarantee the integrity of the job being processed.Initial Actions• If the job has mixed originals, make sure that Mixed Size Originals is selected on the UI.• Switch off the machine, then switch on the machine, GP 14.ProcedurePerform the following:• Perform 03-315, 325, 347, 348, 349, 355, 400, Image Processor PWB Failure RAP.• Install a new image processor PWB, (32-55 ppm) PL 3.20 Item 3 or (65-87 ppm) PL 3.10Item 3.• Perform SCP 6 Final Actions.19-710, 19-711 Firewire Image Transfer Fault RAP19-710 Firewire has failed to transfer image data after its maximum number of retries19-711 Firewire has failed to acknowledge image transfer within firewire time-out.Initial Actions• Switch off the machine, then switch on the machine, GP 14.ProcedurePerform the following:• Perform 03-340, 03-416 image Processing PWB to network Controller Fault RAP.• Install a new components as required:– Firewire PWB, (32-55 ppm) PL 3.15 Item 6, (65-87 ppm) PL 3.11 Item 7.– Image processor PWB, (32-55 ppm) PL 3.20 Item 3 or (65-87 ppm) PL 3.10 Item 3.• Perform SCP 6 Final Actions.