August 20072-356 WorkCentre 5687 Family11-300-120, 11-302-120, 11-303-120Status Indicator RAPs11-300-120, 11-302-120, 11-303-120 Interlocks RAP11-300-120 The docking interlock is open during run mode.11-302-120 The top cover interlock is open during run mode.11-303-120 The front door interlock is open during run mode.Initial ActionsCheck the 1K LCSS PWB DIP switch settings, refer to 11E-120 1K LCSS PWB DIP SwitchSettings RAP.Check the following:• The 1K LCSS is installed correctly, refer to REP 11.13-120.• The 1K LCSS front door is closed.• The 1K LCSS top cover is closed.ProcedureNOTE: In diagnostics, actuating any 1K LCSS sensor or switch can change the displayed stateon the UI. Make sure that the correct sensor or switch is tested.Go to Flag 1. Check for +24V on P/J5 pin 1. If the voltage is not present, refer to 11C-120 1KLCSS Power Distribution RAP.Go to the appropriate RAP:• 11-300-120 Docking Interlock RAP• 11-302-120 Top Cover Interlock RAP• 11-303-120 Front Door Interlock RAP11-300-120 Docking Interlock RAPWARNINGTake care not to topple the LCSS.The LCSS is unstable when undocked from the machine.Do not show the customer how to undock the LCSS.Undock the 1K LCSS, refer to REP 11.11-120. Figure 1, check the docking interlock switch,S11-300 as follows:• While supporting the 1K LCSS, slide the 1K LCSS 5cm (2 inches) away from themachine. Check the interlock actuator on the machine is not damaged or missing.NOTE: The wiring harness passes underneath the docking interlock switch housing. Ifthis harness is not correctly positioned, the switch can be mis-located, giving intermittentdocking interlock problems.• Enter dC330, code 11-300, docking interlock switch, S11-300. While supporting the 1KLCSS, slide the 1K LCSS 5cm (2 inches) away from the machine to de-actuate S11-300.If the display does not change, refer to:– GP 13, How to Check a Switch– P/J6, 1K LCSS PWB• Go to Flag 1. Check the wiring between P/J5 and S11-300.• If necessary, install a new docking interlock switch, PL 11.102 Item 2.11-302-120 Top Cover Interlock RAPCheck the top cover interlock switch, S11-302 as follows:• Check the switch actuator.• Enter dC330, code 11-302, top cover interlock switch, S11-302. Actuate S11-302. If thedisplay does not change, refer to:– GP 13, How to Check a switch– Figure 2.– P/J5, 1K LCSS PWB• Go to Flag 3. Check the wiring between P/J5 and S11-302.• If necessary, install a new top cover interlock switch, PL 11.124 Item 6.11-303-120 Front Door Interlock RAPCheck the front door interlock switch, S11-303 as follows:• Check the switch actuator.• Enter dC330, code 11-303, front door interlock switch, S11-303. Actuate S11-303. If thedisplay does not change, refer to:– GP 13, How to Check a switch– Figure 2.– P/J51K LCSS PWB• Go to Flag 2. Check the wiring between P/J5 and S11-303.• If necessary, install a new front door interlock switch, PL 11.124 Item 5.Perform SCP 6 Final Actions.