5.10 o: Operator Related SettingsYASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual 285Parameter Details5■ o1-04: V/f Pattern Display UnitDetermines the units used for the frequency reference when setting parameters that create the V/f pattern: E1-04, E1-06,E1-09, E1-11, and E2-04. For motor 2, this includes parameters E3-04, E3-06, E3-07, E3-09, and E3-11.Enabled only in vector control modes (CLV, AOLV/PM, CLV/PM).Setting 0: HertzSetting 1: r/minNote: For motor 2, o1-04 can only be set to 0 for Hertz.■ o1-10: User-Set Display Units Maximum ValueDetermines the display value that is equal to the maximum output frequency.■ o1-11: User-Set Display Units Decimal DisplayDetermines how many decimal points should be used to set and display the frequency reference.Setting 0: No decimal pointSetting 1: One decimal pointSetting 2: Two decimal pointsSetting 3: Three decimal points◆ o2: Digital Operator Keypad FunctionsThese parameters determine the functions assigned to the operator keys.■ o2-01: LO/RE (LOCAL/REMOTE) Key Function SelectionParameter o2-01 determines whether the LO/RE key on the digital operator will be enabled or not for switching betweenLOCAL and REMOTE.Setting 0: DisabledThe LO/RE key is disabled.Setting 1: EnabledThe LO/RE switches between LOCAL and REMOTE operation. Switching is possible during stop only. When LOCALis selected, the LED indicator on the LO/RE key will light up.WARNING! Sudden Movement Hazard. The drive may start unexpectedly if the Run command is already applied when switching fromLOCAL mode to REMOTE mode when b1-07 = 1, resulting in death or serious injury. Check all mechanical or electrical connectionsthoroughly before making any setting changes to o2-01 and b1-07. Table 5.41 lists the setting combinations for o2-01 and b1-07.Table 5.41 LO/RE Key and b1-07No. Name Setting Range Defaulto1-04 V/f Pattern Display Unit 0 or 1 Determined by A1-02No. Name Setting Range Defaulto1-10 User-Set Display Units Maximum Value 1 to 60000 Determined by o1-03No. Name Setting Range Defaulto1-11 User-Set Display Units Decimal Display 0 to 3 Determined by o1-03No. Name Setting Range Defaulto2-01 LO/RE Key Function Selection 0 or 1 1o2-01 b1-07 Switch from LOCAL to REMOTE Switch from REMOTE to LOCAL0 0 Not possible Not possible1 Not possible Not possible10 Will not run until a new Run command is entered. Run not possible1If a Run command is entered, the drive will start running assoon as the LO/RE key is pushed to change from LOCAL toREMOTE.Run not possible