A.2 Three-Phase 200 V Class DrivesYASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual 389SpecificationsAA.2 Three-Phase 200 V Class DrivesTable A.2 Power Ratings (Three-Phase 200 V Class)Item<1> The motor capacity (kW) refers to a Yaskawa 4-pole motor. The rated output current of the drive output amps should be equal to or greater thanthe motor rated current.<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiringconnections, and power supply impedance.<3> Rated motor capacity is calculated with a rated output voltage of 220 V.<4> Carrier frequency is set to 2 kHz. Current derating is required in order to raise the carrier frequency.<5> Carrier frequency can be increased up the 8 kHz while keeping this current rating. Higher carrier frequency settings require derating.<6> Carrier frequency can be increased up the 5 kHz while keeping this current rating. Higher carrier frequency settings require derating.SpecificationCIMR-A2A 0004 0006 0010 0012 0021 0030 0040 0056 0069 0081 0110 0138 0169 0211 0250 0312 0360 0415Maximum Applicable MotorCapacity (kW) <1>HD Rating 0.55 1.1 1.5 2.2 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110ND Rating 0.75 1.1 2.2 3 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 110InputInput Current (A) <2> HD Rating 2.9 5.8 7.5 11 18.9 28 37 52 68 80 82 111 136 164 200 271 324 394ND Rating 3.9 7.3 10.8 13.9 24 37 52 68 80 96 111 136 164 200 271 324 394 471Rated VoltageRated Frequency Three-phase 200 to 240 Vac 50/60 Hz/270 to 340 VdcAllowable Voltage Fluctuation -15 to 10%Allowable Frequency Fluctuation ±5%Input Power (kVA) HD Rating 1.3 2.2 4.1 5.8 9.5 14 18 27 36 44 37 51 62 75 91 124 148 180ND Rating 2.2 3.1 5.8 7.8 14 18 27 36 44 52 51 62 75 91 124 148 180 215OutputRated Output Capacity(kVA) <3>HD Rating 1.2 1.9 3 4.2 6.7 9.5 12.6 17.9 23 29 32 44 55 69 82 108 132 158ND Rating 1.3 2.3 3.7 4.6 8 11.4 15.2 21 26 31 42 53 64 80 95 119 137 158Rated Output Current(A)HD Rating 3.2<5>5<5>8<5>11<5>17.5<5>25<5>33<5>47<5>60<5>75<5>85<5>115<5>145<6>180<6>215<6>283<6>346<6>415<4>NDRating <4> 3.5 6 9.6 12 21 30 40 56 69 81 110 138 169 211 250 312 360 415Overload ToleranceHD Rating: 150% of rated output current for 60 s(Derating may be required for applications that start and stop frequently)ND Rating: 120% of rated output current for 60 sCarrier Frequency User adjustable between 2 and 15 kHz User adjustable between 2 and 10 kHzMaximum Output Voltage (V) Three-phase 200 to 240 V (proportional to input voltage)Maximum Output Frequency (Hz) 400 Hz (user-set)