Chapter 55-15.1 Construction5.1.1 Specifications, Controls, and Functions 0010-7881iR7105 / iR7095The specifications, controls, and functions of the machine's original exposure system are as follows:T-5-1Item DescriptionScanning lamp xenon lampOriginal scanning book mode: by moving the scannerADF mode (one-side reading): by stream reading (2 fixed points of small-sizereading and large-size reading)ADF mode (double-sided reading): by moving the scanner (Fixed reading)Original reading resolution 600 x 600 dpi (main scanning x sub scanning)Halftone 256 gradationsScanning position detection by scanner HP sensorlens single-focal point, fixed typeMagnification [1] in platen mode, Fixed reading: 25% to 400%main scanning direction: image processing by controller blocksub scanning direction: scanning speed variation (No. 1 mirror base; 100% orhigher)in combination with image processing by reader block (50% or higher and lowerthan 100%)in combination with image processing in reader block and controller block (lowerthan 50%)[2] ADF mode: 25% to 200%main scanning direction: image processing in controller blocksub scanning direction: original movement speed variation (89% or higher)in combination with image processing by reader block (50% or higher and lowerthan 89%)in combination with image processing in reader block and controller block (lowerthan 50%)Scanner drive control No. 1/2 mirror base: control by pulse motorScanning lamp control [1]activation control by pulse motor[2]error detection control