Chapter 22-19F-2-5712) Disconnect the connector [1], and release the locking lever [2] of the pre-transfer charging assembly; then, remove the pre-transfer charging as-sembly [3].Clean the pre-transfer charging assembly using alcohol.F-2-5813) While keeping it unlocked, fit in the primary charging assembly, andconnect the connector.14) While keeping it unlocked, fit the pre-transfer charging assembly inplace, and connect the connector.15) Mount the double-feeding detection PCB (reception).16) Mount the primary charging assembly front cover and the pre-transfercharging assembly cover.17) Close the front cover.2.2.8 Mounting the Developing Assembly 0010-8950iR7105 / iR7095 / iR7086 / iR7095P1) Open the manual feed cover.2) Remove the tape [1]; then, remove the hopper supply mouth cover [2].F-2-593) Holding the developing assembly [1] as shown, fit it in place in the ma-chine.F-2-604) Connect the connectors [1], [2].Check to make sure that the solvent on the primary charging assembly andthe pre-transfer charging assembly is fully dry.Check to be sure that the one-way arm [1] of the pre-transfer chargingassembly is on the eccentric cam [2].[1][2] [3][1][2][3]When mounting the developing assembly, take care not to hit against thedeveloping cylinder [2].Check to be sure that the connector will not become disconnected. Poorcontact will lead to blank prints.[1][2][1][2][1][2]