Chapter 1313-513.3.2 Scheduled Servicing Chart 0010-9512iR7105 / iR7095 / iR7086Do not use solvents other than those indicated.T-13-511 Clean the fixing/delivery assembly.- separation claw (upper, lower)- transport rollers- inlet guide- web (check)- web oil receptacle- thermistor- sub thermistor- thermal switch12 Clean the cleaner assembly.- side scraper13 Clean the duplexing assembly.- duplexing horizontal registration sensor14 Clean the copyboard glass.15 Make test prints.16 Make sample prints.17 Press the leakage breaker test switch to see the breakeroperates normally. Thereafter, turn off the power switch,and shift the lever to ON position; then, turn the powerswitch back on.Press the test switch while the power switch is in ONposition and, in addition, the lever [1] of the leakagebreaker is also in ON position. If normal, the breakerwill go off to cut the power. (If you are replacing it,pay attention to its orientation.)If you have replaced the leakage breaker, be sure tocheck the breaker after replacement.Check to see that the grounding is proper. Otherwise, the leakage breaker may fail to go on in the event of a leak.18 Put sample prints in order, and clean up the area aroundthe machine.19 Record the most recent counter reading.20 Update the service book, and report to the person incharge.Record the history of checks made on the leakagebreaker.Unit name Location Maintenance intervals Remarksupon installation every 500,000printsevery 1,000,000printsExternals/controls copyboard glass cleanozone filter(FM2, FM8, FM20)clean replace Remove the dust from the filter surface.No. Step Work Remarks[1]