Installing the IBM 6Gb Performance Optimized Host BusAdapterUse the information for instructions on how to install the IBM 6Gb PerformanceOptimized Host Bus Adapter.About this task6 Gb Performance OptimizedHost Bus AdapterPort 1 Port 0You can purchase an optional IBM 6 Gb Performance Optimized Host Bus Adapter.This solid-state drive controller provides no RAID support; however, it helps toprovide optimized performance for applications that do not need RAID support.This adapter can be installed in the PCIe slots listed in “Supported adapters” onpage 72. For configuration information, see the documentation that comes with theadapter.Attention: Some cluster solutions require specific code levels or coordinated codeupdates. If the device is part of a cluster solution, verify that the latest level ofcode is supported for the cluster solution before you update the code.Note:v For additional information and notes about installing the adapters “Installing anadapter” on page 70.v Follow the general rule for connecting the SAS signal cables to the adapter anddrive backplane: port 0 on the adapter to port 0 on the drive backplane and port1 on the adapter to port 1 on the drive backplane (depending on the type ofdrive backplane you install in the server).To install the adapter, complete the following steps:Procedure1. Read the safety information and installation guidelines, see “Safety” on page viiand “Installation guidelines” on page 35.2. Turn off the server (see “Turning off the server” on page 22) and all attachedperipheral devices. Disconnect all power cords; then, disconnect all externalcables from the server.3. Remove the top cover (see “Removing the server top cover” on page 38).4. Remove the fan cage assembly (see “Removing the fan cage assembly” on page42).86 System x3750 M4 Types 8722 and 8733: Installation and Service Guide