98 IBM xSeries 130: User’s ReferenceDiagnostic error message tablesThe following tables provide descriptions of the error messages that might appearwhen you run the diagnostic programs.Important:If diagnostic error messages appear that are not listed in the following tables,make sure that your appliance server has the latest levels of BIOS anddiagnostics microcode installed.Table 15. Diagnostic error messages.Code Function Result Text message Action001 Core system Failed Processor board, ECC Test Call for service.System board005 Video port Processor and system boards011 Serial port Integrated serial port014 Parallel port Integrated parallel port015 USB interface Aborted Can NOT test USB interface while it is in use.Note: If you have a USB keyboard or mouseattached, you cannot run the diagnosticprogram for the USB interface.1. Turn off theappliance server.2. Replace the USBkeyboard andmouse with astandard keyboardand mouse.3. Turn on theappliance server.4. Run the diagnostictest again.Failed System board Call for service.020 PCI interface Failed System board Call for service.030 SCSI interface Failed SCSI adapter in slot n failed register/counter/ powertest(where n is the slot number of the failing adapter)Refer to the informationprovided with theadapter for instructions.If the problem persists,call for service.SCSI controller on system board failedregister/counter/power testCall for service.075 Power supply Failed Voltage sensed by the system is out of range Call for service.