User Guide211www.nec-computers.com0B28 Unsupported Processor detected onProcessor 1.Make sure that the server supports the CPU. If youare not sure, contact your service representative torequest the maintenance.0B29 Unsupported Processor detected onProcessor 2.0B30 FAN1 Alarm occurred. Contact your service representative to replace thefan.0B31 FAN2 Alarm occurred.0B32 FAN3 Alarm occurred.0B5F Forced to use Processor with error Because an error is detected in every CPU, thesystem is forcibly started. Contact your servicerepresentative.0B60 DIMM group #1 has been disabled Contact your service representative.0B61 DIMM group #2 has been disabled0B62 DIMM group #3 has been disabled0B63 DIMM group #4 has been disabled0B64 DIMM group #5 has been disabled0B65 DIMM group #6 has been disabled0B70 The error occurred during temperaturesensor reading.Contact your service representative.0B71 System Temperature out of the range. Contact your service representative to replace thefan.0B74 The error occurred during voltage sensorreading.Contact your service representative.0B75 System voltage out of the range.0B80 BMC Memory Test Failed. Turn off the power once and then on again to start theserver. If the error cannot be corrected, contact yourservice representative.0B81 BMC FirNEC MWAre Code Area CRC checkfailed.0B82 BMC core Hardware failure.0B83 BMC 1BF or 0BF check failed.0B8A BMC SEL area full Clear the system event logs using the BIOS SETUPutility.0B8B BMC progress check timeout. Turn off the power once and then on again to start theserver. If the error cannot be corrected, contact yourservice representative.0B8C BMC command access failed.0B8D Could not redirect the console - BMC Busy -0B8E Could not redirect the console - BMC Error -0B8F Could not redirect the console - BMCParameter Error -0B90 BMC Platform Information Area corrupted.0B91 BMC update firmware corrupted.0B92 Internal Use Area of BMC FRU corrupted. This is not a fatal error. Turn off the power once andthen on again to restart the server. If the error cannotbe corrected, contact your service representative.0B93 BMC SDR Repository empty. Turn off the power once and then on again to restartthe server. If the error cannot be corrected, contactyour service representative.0B94 IPMB signal lines do not respond. This is not a fatal error. Turn off the power once andthen on again to restart the server. If the error cannotbe corrected, contact your service representative.0B95 BMC FRU device failure.Table 28: POST Error Messages (Continued)ErrorcodeError message Recommended Action