User Guide84www.nec-computers.comBoot MonitoringPolicyRetry 3 TimesRetry Service BootAlways ResetSpecifies what happens when atime out is detected during bootmonitoring.When Retry 3 Times isselected, the system is resetafter a time out occurence, andtries 3 times to boot the OS.When Retry Service Boot isselected, the system is resetafter a time out occurence, andtries 3 times to boot the OS.The system then tries to bootfrom the service partition (3times).When Always Reset isselected, the system is resetafter the time out occurence,and tries repeatedly to boot theOS.Thermal Sensor DisabledEnabledSpecifies whether the thermalsensor monitoring function isenabled or not.If a thermal error is detectedwhile this parameter is enabled,the system stops at the end ofthe POST.BMC IRQ DisabledIRQ 11Determines the routing of theBMC Interrupt.POST Error Pause DisabledEnabledSpecifies whether the systemwaits for user intervention oncritical POST errors.If no keyboard is connected tothe system, this option isignored and the system alwayscontinues to bootup.AC-LINK Stays OffLast StatePower OnSets the AC-LINK feature.Determines the mode ofoperation if a power lossoccurs.Power On DelayTime (Sec)0 - 255 Sets the power-on delay timewhithin a 0 to 255 secondsrange.This parameter is valid when“Power On “ or “Last State” isspecified for AC Link.Platform EventFilteringDisabledEnabledThis item is meaningless whenthe notification feature of theRemote Management Card isenabled.Table 15: Server Menu (Continued)Feature Choices orDisplay OnlyDescription Your Setting